P O R T A L T I +
Portal Installation Manual
23
Document #: PTL1001
Each wash manufacturer has its own specific color code system and wash relay pin-outs;
therefore, it is important to review the appropriate wash documentation prior to beginning this
portion of the installation.
3.7.2
Wiring the Wash Relay Interface
To wire the wash relays, connect the wires that come from the PLC to the appropriate pin
numbers in the phoenix connector using the following procedures:
Note:
The wiring for the Portal TI+ Wash I/O board is the same as the wiring for the Wash
Select II wash interface.
3 . 7 . 2 . 1
P r e p a r a t i o n
You will need a thin tipped, flat head screwdriver to open and tighten the relay connections of
the Phoenix connector.
Review the wash manufacturer’s documentation to determine the color codes for the wiring of
the wash pin-outs for your wash equipment before beginning this installation.
Phoenix connectors are shipped already inserted in the appropriate sockets on the Wash I/O
board.
1.
Remove the Carrier Board/Wash I/O Board Cover Plate using a 5/16” socket wrench.
2. Locate the Wash I/O board on the inside lower right-hand wall of the Portal TI+ case.
3. On the Wash I/O Board, locate the 10-pin Phoenix connector labeled J17 on the lower
right-hand corner of the Wash I/O board.