2 9
T r o u b l e s h o o t i n g
M AB 5 2 5
ENGLISH
T r o u b l e s h o o t i n g
F a u l t s - c a u s e s a n d r e m e d i e s
F a u l t
Po s s i b l e c a u s e
R e m e d y
The motor does not start
after pressing the ON/
OFF switch or stops during
operation .
Plug not inserted into socket . Insert plug .
Automatic circuit breaker
tripped .
Switch on the automatic circuit
breaker again .
The magnetic clamp is not
switched on .
Switch on the magnetic clamp .
The internal safety switch
has switched off the machine
due to overheating .
Allow the machine to cool
down .
Direction of rotation not
selected .
Preselect direction of rotation .
The torque cut-out has
tripped .
Switch the machine off and on
again .
The automatic circuit
breaker in the electrical
distribution board trips
Too many appliances con-
nected to the same power
circuit .
Reduce the number of appli-
ances on the power circuit .
Machine is defective .
Contact After-sales Service .
The magnetic clamp does
not function .
Magnet not switched on .
Switch on magnet .
The surface is not magnetic .
Use a suitable base .
The lubrication system
does not function .
No lubricant available .
Top up the lubricant .
Lubricant tap closed .
Open the lubricant tap .
Connecting nipple clogged .
Clean tank and nipple .
NOTE
►
If you cannot resolve the problem with the steps described above, please contact
After-Sales Service .