background image

output

November 19, 2019

13:11

Page 10

 

 

 

 

SulfiLogger_Manual_EN_203.pdf

Sul

fiL

ogger™

Installation

manual

Re

vision

1.01

(V

alid

from

June

2019)

I

N

T

R

O

D

U

C

T

IO

N

This

guide

co

vers

the

steps

required

to

in-

stall

the

Sul

fiL

ogger

sensor

,including

the

electrical

and

mechanical

installation

pro-

cedures.

For

further

information

about

the

use

and

maintenance

of

the

product,

we

kindly

refer

to

the

latest

User

Manual

avail-

able

at

www

.Sul

fiL

ogger

.com

.

W

arr

anty

and

legal

information

are

described

in

the

terms

and

conditions

of

your

order

con

fir-

mation

and

also

available

upon

request.

S

A

FE

T

Y

Please

read

this

manual

carefully

before

un-

packing,

installing

or

oper

ating

the

de

vice.

Although

the

oper

ation

of

the

Sul

fiL

ogger

sensor

is

str

aightforward,

it

is

mandatory

to

be

familiar

with

the

content

of

this

manual.

Failure

to

do

so

ma

y

result

in

serious

injury

to

oper

ators

or

other

persons,

or

damage

to

equipment.

Do

not

use

or

install

the

Sul-

fiL

ogger

sensor

and

auxiliary

equipment

in

an

y

other

wa

y

than

speci

fied

in

this

man-

ual.

Special

attention

must

be

paid

to

all

danger

and

caution

statements.

Do

not

use

the

Sul

fiL

ogger

sensor

outside

the

speci-

fied

electrical,

mechanical

and

thermal

pa-

rameters

as

speci

fied

in

the

data

sheet.

Dur-

ing

the

installation,

please

wear

personal

protectiv

e

equipment

(PPE)

according

to

the

safety

regulation

of

the

installation

site.

Hazard

statement

nomenclature

D

ANGER

Indicates

a

potentially

or

imminently

hazardous

situation

which,

if

not

av

oided,

could

result

in

death

or

seri-

ous

injury

.

!

CA

UTION

Indicates

a

potentially

hazardous

situ-

ation

that

ma

y

result

in

minor

or

mod-

er

ate

injury

.

IMPOR

TANT

NO

TE

Information

that

requires

special

em-

phasis.

Hazardous

areas

-Sul

fiL

ogger™

sensor

EX

version

Pa

y

close

attention

to

other

EX

equip-

ment

used

in

conjunction

with

the

Sul-

fiL

ogger™

sensor

.

Observ

e

the

speci

fications

in

th

e

certi

fi-

cate

as

well

as

national

and

local

regula-

tions.

Ensure

that

all

personnel

are

suitably

quali

fied.

Alwa

ys

use

appro

ved

EX

barriers

for

in-

stallation.

Chemical

and

gas

handling

safety

D

ANGER

Handling

hazardous

gases

such

as

hy-

drogen

sul

fide

or

chemical

samples

containing

dissolv

ed

sul

fides

can

be

dangerous.

Users

of

this

product

are

advised

to

familiarize

themselv

es

wi

th

safety

procedures,

use

of

personal

pro-

tectiv

e

equipment

(PPE)

and

the

cor-

rect

use

of

gases

and/

or

chemicals,

and

to

carefully

read

all

rele

vant

Safety

Data

Sheets.

Installation

and

calibr

ation

of

the

Sul

fiL

og-

ger

sensor

ma

y

include

the

risk

of

con-

tact

with

hazardous

gases

or

liquids.

Hy

dro-

gen

sul

fide

is

a

highly

to

xic

gas

and

special

precautions

are

needed

to

av

oid

the

risk

of

injury

or

death.

Furthermore,

the

installa-

tion

of

the

Sul

fiL

ogger

sensor

in

applica-

tions

such

as

sewer

networks

or

other

facil-

ities

containing

ra

w

wastewater

includes

a

risk

of

contact

with

a

range

of

other

chem-

ical

and

biological

threats,

and

an

y

oper

a-

tor

performing

installation

or

service

on

the

Sul

fiL

ogger

sensor

in

such

en

vironments

should

therefore

be

tr

ained

in

the

en

viron-

mental

safety

and

need

of

PPE

for

the

giv

en

application.

This

manual

does

not

co

ver

an

y

such

tr

aining.

The

use

of

the

Sul

fiL

ogger

sensor

for

speci

fic

applications

ma

y

in

volv

e

risks

that

are

not

mentioned

here.

O

V

ER

V

IE

W

The

Sul

fiL

ogger

sensor

is

available

in

dif-

ferent

con

figur

ations

in

an

ATEX

certi

fied

version

(X1

sensors)

and

a

non-

ATEX

certi-

fied

version

(S1

sensors).

If

your

product

is

an

ATEX

certi

fied

product,

it

is

crucial

that

you

carefully

follow

the

instructions

re-

lating

to

ATEX

speci

fic

installa

tion

require-

ments.

EU

-A

TEX

certi

fication

The

Sul

fiL

ogger™

X1

sensor

has

the

follow-

ing

marking:

E

LE

C

T

R

IC

A

L

IN

ST

A

LL

A

T

IO

N

Barriers

for

Sul

fiL

ogger™

X1

installation

When

using

the

Sul

fiL

ogger

sensor

,

a

Zener

barrier

or

EX

isolator

MUST

alwa

ys

be

used.

W

e

recommend

using

barriers

tested

and

appro

ved

by

Unisense.

Hazar

dous ar

ea

Saf

e ar

ea

A

ppar

atus

e.g

. SC

AD

A

Zener bar

rier

4-20 mA / po

w

er

EX isola

tor

or

RS

-232

Zener bar

rier

EX isola

tor

or

Connection

The

Sul

fiL

ogger

sensor

has

two

connec-

tors:

A

4-20

mA

power

connector

(5-pin

M12

male

)and

an

RS-232

connector

(5-pin

M12

female

).

W

e

recommend

using

M12

plugs

in

stainless

steel

(EN

1.4404

/316L).

These

cables

can

be

pro

vided

by

Unisense.

Please

note

that

products

powered

by

a

battery

bo

x

ma

y

require

special

attention.

Please

refer

to

the

latest

User

Manual.

Port

par

ameters

Please

note

that

the

colors

listed

here

only

apply

for

cables

supplied

by

Unisense.

The

Sul

fiL

ogger

is

designed

for

4-20

mA

loop-

power

.Howe

ver

,this

connector

can

also

be

used

only

for

DC

supply

.

Power

/4-20

mA

Pin

Color

Connection

1

Brown

Positiv

e

(+12

to

24

v)

2

White

Not

connected

3

Blue

Negativ

e

(-)

4

Black

Not

connected

5

Gr

ay

Not

connected

Communication

(RS-232)

Pin

Color

Connection

1

Brown

TXD

2

White

Not

connected

3

Blue

RXD

4

Black

GND

5

Gr

ay

Not

connected

Grounding

The

Sul

fiL

ogger

sensor

should

alwa

ys

be

grounded.

Howe

ver

,national,

regional

or

local

regulation

ma

y

apply

.

For

use

in

ATEX

-regulated

areas,

see

EN/IEC

60079-

14.

Unisense

recommends

that

the

Sul

fiL

og-

ger

sensor

is

alwa

ys

grounded

using

the

M6

thread

at

the

back

of

the

de

vice

for

a

secure

grounding

connection.

D

ANGER

Using

a

Sul

fiL

ogger

sensor

from

the

X1-series

without

grounding

will

void

the

ATEX

certi

ficate.

A

PPENDIX

: I

NSTALLATION GUIDE

10

Summary of Contents for SULFILOGGER

Page 1: ...SulfiLogger_Manual_EN_203 pdf SulfiLogger User Manual COPYRIGHT 2019 UNISENSE A S VALID FOR SERIAL NUMBERS FROM S N 1004000 REV 2019 11 19...

Page 2: ...leaning 4 Calibration 4 Operating principles 5 Electrochemical measurements of hydrogen sulfide 5 Measuring in different media unit conversions 5 Specifications 6 SulfiLogger sensors 6 Technical speci...

Page 3: ...ut of the use the results of use or the inability to use this product Unisense A S assumes no liability for damages on instruments designed for indoor use due to unintended field use or exposure to du...

Page 4: ...ulfiLogger X1 series sensors only EX Pay close attention to other EX equipment used in conjunction with the SulfiLogger sensor Observe the specifications in the certificate as well as national and loc...

Page 5: ...fiLogger X1 and standard versions of the sensor are labeled SulfiLogger S1 If your product is an ATEX certified product X1 series sensors it is very important that you carefully follow the instruction...

Page 6: ...lled using a flow cell please detach the sensor from the flow cell before starting the calibration If needed replace the O ring on the sensor before re installation 1 2 3 4 5 6 SUCCESS FAILURE 6 1000...

Page 7: ...of the daily variations in ventilation conditions in the head space of the sewer and it is independent of the exact mounting position of the sensor in the liquid the sulfide concentration is fairly ho...

Page 8: ...t 1 of full range Operating humidity range 0 100 Design temperature range 20 C to 60 C 4 F to 140 F Operating temperature range 0 C to 40 C 32 F to 104 F MECHANICAL SPECIFICATIONS Length 240 mm Diamet...

Page 9: ...lose to the end of pipe of the force main as possible to get a realistic measure of the initial H2S concentration The SulfiLogger S1 X1 1120 5mgL sensor can be mounted at access points directly on the...

Page 10: ...hould be stated on the bottle or can be provided by the vendor If judging the accuracy of the SulfiLogger sensor based on liquid phase measurements there are various ways to do this all of which are p...

Page 11: ...Logger sensor is temperature compensated the accuracy of the sensor is highest if the calibration is done at a temperature close to the temperature of subsequent measurements Problem During a calibrat...