Work Zone GMP Manual
08/25/2022
17
6.2.3 Set Up: Basic set up & Advance set up are included as below
Basic set up
Enter the Advanced settings, enter the password (initial password “
80000000
”), then press
the Confirm button to enter.
Options
Adjustable value
Default
Description
Game time
30-60 Sec
60 Sec
The game time of each round.
Coins/game
1-20
1
The number of coins for each game.
Win Rate
2-999
2
Set how many rounds of the game to win a
prize.
*: (If you change the Win rate, the number of players' games will not be cleared, and will be
counted in the next round of winnings.
If you need to calculate from O, please clear the account).
Game mode
Keep/Lck/Rnd
Keep
Set the game mode.
Please see 8.3 for detail instruction.
Max Pwr Cnt
(Assuring
times)
0-5
5
0 means that when the strong claw power
comes, there will be an unlimited number of
powerful claw until win the prize;
1 means when the strong claw power comes,
if cannot win the prize, will only give 1
chance for strong claw power.
Claw Strength
Please see
6.2.3.1
/
Adjust claw power
Drop
Mode A/
Mode B/Mode C
/
Drop the prize
Please see 8.4 for detail instruction.
Cable length
/
/
Adjust the descending length of the claw to
the bottom of the prize.
Move speed- X
Speed
(Left and right)
40-100
75
Motor speed.
The larger the value, the faster the speed.
Move speed- Y
Speed
(Front and rear)
40-100
85
Motor speed.
The larger the value, the faster the speed
Move speed- Z
Speed
(Up and down)
40-100
40
Motor speed.
The larger the value, the faster the speed
Position
X:
Y:
/
The Prize drop position.
Key delay
0-99ms
0ms
There is a delay when using the joystick.
CLED
UnSync/Mst/Slv
UnSync
Color LED
Clear Bill
Clear accounts and player play times.
Password
Modify the password to enter the advanced
setting.
Note: Basic set up initial passwords can be changed by operator in
“Password” option