UNIS CUBE II Operating Manual Download Page 2

OPERATING MANUAL FOR 

CUBE II

 

 

 

ver.: uniscool v1.3 

 

 

 
Dear Customer,  

 
thank you for purchasing the product of the company UNIS COOL sro, which is a long-time successful manufacturer and 
supplier of a specialized range of professional refrigeration and catering equipment. We believe that with the help of this 
facility you will attract a lot of attention to the exhibited goods and your guests will be happy to return. 
 
 
 

 Symbols used in this manual

 

 
 

SYMBOL 

MEANING 

 

These  symbols  are  the  "

WARNING

"  and  "

CAUTION

"  and  point  to  the  fact  that  the  activity  can  cause 

damage and / or serious injury to the user. 

 

 

This symbol indicates an important instruction, property, process or matter, which is necessary during the 
servicing and maintenance of equipment comply or be aware of. 

 

Symbol points to useful information related to the device or accessories. 

 

Symbol is a reference to another section of this manual. 

 
 
 

 For whom is the guidance intended 

 
This  manual  is  intended  for  all  persons  who  come  into  contact  with  the  device  during  the  installation,  operation  and 
maintenance. Each of these persons must be thoroughly familiar with its content before beginning any activity with the 
device. 
 
 

 Necessary notice 

 
Carefully follow the instructions therein, to make the use of equipment, but also ensure its optimum use and long life.  
 

Do  not  turn-on  the  unit  until  you  are  thoroughly  familiar  with  all  instructions,  restrictions  and 
recommendations that are included in this manual, especially the chapter "Safety in use".  

 
The illustrations used in this manual may not always agree with reality; their purpose is to describe the main principles 
of the device. 
 
 

 If you are unsure 

 
In practice there are often unpredictable situations that can not be included in this instruction and described. Therefore, 
whenever you are not sure, contact your supplier.  
 
When contacting the supplier or trained technicians, please prepare the basic data on the device.  
 
You can read the nameplate, located in the upper right corner of the enclosure cooling units, see the last page. 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CUBE II

Page 1: ...Refrigerated showcase CUBE II Operating manual...

Page 2: ...ce intended This manual is intended for all persons who come into contact with the device during the installation operation and maintenance Each of these persons must be thoroughly familiar with its c...

Page 3: ...e stored under the following conditions 1 Showcase should be kept in their original packaging in a dry and dark place 2 Do not turn upside down nor to side the showcase Do not place any objects on it...

Page 4: ...tivities the equipment manufacturer is not liable the risk is covered by the user solely 2 2 Improper use Showcase is not intended to chill the merchandise on display Showcase is not intended for perm...

Page 5: ...OPERATING MANUAL FOR CUBE II 3 2 4 Dimensions CUBE II 600 1000 1500 CUBE II 45 CORNER More of technical information can be found in Chapter 9...

Page 6: ...OPERATING MANUAL FOR CUBE II 4 2 5 Versions Standard serve over Self service 45 neutral corner...

Page 7: ...3 2 Assembling 1 Showcase should be align to the horizontal position by using the adjustable feets on the bottom of the display case Align the showcase by turning the adjustable feet with wrench nr 24...

Page 8: ...oltage 230V 50 Hz The power supply socket must be separately grounded and protected by a fuse of 10A or 16A Other devices must not be attached to this separately fused circuit 3 4 Before first turn on...

Page 9: ...ead to fall and cause injury 4 2 While using the showcase If the device is damaged in any way turn it off immediately unplug it from the power supply and contact your supplier Operate the control pane...

Page 10: ...it is cooled for further circulation The collection drainage and evaporation of condensate from the evaporator is done automatically The device is equipped with automatic defrosting set by the manufa...

Page 11: ...lows the circulation of air inside the display case and raises its temperature The front vents and rear exhaust vents must not be covered by goods or other items Also the space between the shelves and...

Page 12: ...Basin and evaporator bottom space Cleaning 6 3 Regularly The power supply cable Control 6 4 Doors gasket Cleaning 6 1 Daily maintenance Daily clearing of exhibition space from the remnants of the exh...

Page 13: ...the exhibition board Make sure the bottom of the tub with an evaporator is not soiled by debris crumbs if so use a vacuum cleaner to remove them Clean the entire bottom area 6 4 Regular maintenace Reg...

Page 14: ...isplay case can occur during hot humid day or depending on the site of installation It occurs when there is high humidity of ambient air and water from the air is coming into contact with cold surface...

Page 15: ...ice life of showcase expired it must be properly disposed of During the disposal of the showcase and its parts the operator is obliged to follow the procedure under Art 8 REGULATION OF THE EUROPEAN PA...

Page 16: ...9 1 00 1 71 2 60 Weight kg 110 150 200 265 Refrigerant R134a Operation conditions Temperature max 25 o C Humidity max 60 ambient relative humidity Capacity shelves kg 10 Noise Less than 80 dB 9 2 Prod...

Reviews: