Alarms
AL
– Lower temperature alarm – check the cabinet temperature, control parameter A1
(manual of controller is needed)
AH
– Upper temperature alarm - check the cabinet temperature, control parameter A4
(manual of controller is needed)
Errors
Symbol
Type of failure
Correction
P 1
Cabinet probe error
check the probe, check the
integrity of the probe, check
the connection instrument-
probe
P 2
Evaporator probe error
Turn off and turn on
the device. If the
alarm remains on, call
a service company.
Switch off
Switch off the main on/off button. Switch off the lightening switch.
Use
Before placing food inside prechill the counter (let the counter to reach the required cooling
temperature).
Don’t place warm (not chilled) food inside the counter.
Goods mustn’t exceed the edge of shelves.
It is necessary to leave min distance of 3 cm between each shelf.
Front air grids and back air exhaust must be always kept unobstructed, avoid placing goods
or any subjects in front of it
. Improper placing of the goods will slow the air circulation and
increase the temperature of the goods in the counter. The counter is not intended for cooling
down the goods, but to maintain them at the temperature at which they are placed in the
case for its presentation.