background image

5

UNDERSTANDING THE INDICATOR LIGHTS

BATTERY VOLTAGE INDICATOR

BATTERY CAPACITY INDICATOR (non-input from solar panel)

1 2 3 4 5

temperature 
sensor

FULL - 4  indicator lights are lit then turn off. 
3 indicator lights stay lit constantly.

FULL - 3 indicator lights stay lit constantly.

HALF CHARGE - 2 indicator lights stay lit constantly.

NEEDS CHARGING - 1 indicator light stays lit constantly.

14.7 V

13.5 V

13.0 V

12.0 V

< 11.0 V

charging 
indicator

not lit / not charging
lit / charging properly

Summary of Contents for UGP-100WSP

Page 1: ...UGP 100WSP 100 WATT PORTABLE SOLAR PANEL SYSTEM OWNER S GUIDE ...

Page 2: ... and caution must be practiced when installing operating and maintaining the system Record in the space provided below the Serial No and Purchase Date of this appliance Model No UGP 100WSP Type Number _______________________ Serial No ________________________ Purchase Date________________________ Record these numbers for future use IMPORTANT Keep a copy of your bill of sale The date on the bill es...

Page 3: ...le it is open or folded closed Do not expose the solar panel to fire extreme heat or humidity or to extreme temperature changes Do not touch cut or scratch the solar panel with any sharp points or tools Ensure that the solar panel receives adequate ventilation Always keep the solar panel clean of dirt dust and grime Always place the solar panel on a flat surface Always use both fold out steel brac...

Page 4: ... Check the charging indicator light to ensure that the solar panel is operating properly 12V DEEP CELL BATTERY 4 Attach the supporting belt to the back of the solar panel and the steel supporting bracket then adjust the angle as desired 2 Connect the other end of the cable to the battery TO SET UP 1 2 3 4 5 TO DISASSEMBLE 5 4 3 2 1 ...

Page 5: ...e sensor FULL 4 indicator lights are lit then turn off 3 indicator lights stay lit constantly FULL 3 indicator lights stay lit constantly HALF CHARGE 2 indicator lights stay lit constantly NEEDS CHARGING 1 indicator light stays lit constantly 14 7 V 13 5 V 13 0 V 12 0 V 11 0 V charging indicator not lit not charging lit charging properly ...

Page 6: ... battery and charge the battery for a longer period of time LED indicators randomly flash The battery is not properly connected Disconnect the battery and remove all the cables from the solar panel and the battery repeat set up procedure shown on page 3 To maintain the long term and trouble free performance of your solar panel system it is recom mended that you follow these guidelines prior to eac...

Page 7: ... 55A CONTROLLER 12V 10A OUTPUT 12V CONNECTORS Anderson plug MAX CHARGE CURRENT ALLOWED 10A CHARGE VOLTAGE DROP 0 26V DISCHARGE VOLTAGE DROP 0 15V SELF CONSUMPTION 6mA CONTROL VOLTAGE SET VALUE PARAMETERS FOR SEALED DEEP CELL BATTERY EQUALIZING CHARGING VOLTAGE 14 7V 0 1V EQUALIZING CHARGING TIME 0 5 hr BOOST CHARGING 14 7V FLOAT CHARGE VOLTAGE 13 8V 0 1V OVER VOLTAGE PROTECTION 16V START VOLTAGE 5...

Page 8: ...e date WARRANTY CONDITIONS This Warranty does not apply to any appliance that has been subjected to alterations misuse abuse including damage by foreign agents or chemicals accident improper installation or service delivery damage or other than normal household use and service This UNIQUE appliance must be serviced regularly as outlined in the Owner s Manual Neither Unique Gas Products Ltd nor the...

Reviews: