9
IN-LINE FUSE
A 15A in-line fuse is provided with this fridge in order to protect the
wiring.
For 12V operation, use a 15A fuse.
A standard automobile
fuse is recommended and the fuse should be wired to the positive
(“+”) side of the system close to the positive battery terminal.
A 15A fuse is provided with this fridge/freezer. Remove screws from
back plate to access the 15A in-line fuse.
OPERATING VOLTAGE
FUSE
12V
15A
DC POWER CONNECTION
continued
ATTENTION
If a longer connection cable is necessary, the cable cross section (or
gauge) must be equal to or greater than the cable sizes recommended
on the following table. Be careful that the input voltage at the appliance
does not drop below the cut-out voltage of the compressor.
LOW VOLTAGE DISCONNECT
The compressor electronics includes a low voltage disconnect
feature. If the input voltage to the appliance falls below 10.4V (in 12V
mode) or 22.8V (in 24V mode), the compressor will shut-off. Once
the voltage increases above 11.7V (in 12V mode) or 24.2V (in 24V
mode), the compressor will resume normal operation.
This feature is designed to protect the system battery from
experiencing too low a depth of discharge.
CABLE SIZE
12V CABLE
LENGTH
24V CABLE
LENGTH
AREA
AWG
mm
2
/inch Gauge
m
ft
m
ft
2.5 /
3
/
32
”
12
2.5
8
5
16
4 /
5
/
32
”
12
4
13
8
26
6 /
15
/
64
”
10
6
19.5
12
39
10 /
25
/
64
”
8
10
32.8
20
65.6
12V OPERATION
24V OPERATION
SHUT-OFF
10.4V
22.8V
RESTART
11.7V
24.2V