* E1 : Room t emper at ur e sensor t r oubl e -nor mal oper at i on (Appears when both temperature
adjust buttons
▲
,
▼
pushed).
Appears on indoor Eva.sensor trouble -stops the operation.
* E2 : Appears on Error and stops the operation.
* E3 : Normal operation (Appears when both temperature adjust buttons
▲
,
▼
pushed)
* E5 : Appears on Error and stops the operation.
Error types
Room temperature
sensor open
Room temperature
sensor short
Indoor Evaporator open
Indoor Evaporator short
Outdoor
sensor open
Outdoor
sensor short
Outdoor
Accumulator open
Outdoor Accumulator
short
Compressor
error
Communication error
between indoor and
outdoor units.
Display
E1
E1
E1
E1
E2
E2
E2
E2
E3
E5
Operation
• Condition :Under 0.3V(-40 °C)
-> Set room temperature 32 °C, normal operation.
-> Room temperature 'Lo'appears.
-> Disappears when sensor return to normal
• Condition :Over 4.7V(90 °C)
->Set room temperature 32 °C, normal operation.
->Room temperature 'Lo'appears.
->Disappears when sensor return to normal
• Condition :Under 0.3V(-40 °C)
-> Immediately stops the operation showing error mark.
• Condition :Over 4.7V(-90 °C)
->Immediately stops the operation showing error mark.
• Condition :Under 0.3V(-40 °C)
->Immediately stops the operation showing error mark.
• Condition :Over 4.7V(-90 °C)
->Immediately stops the operation showing error mark.
• Condition :Under 0.3V(-40 °C)
->Immediately stops the operation showing error mark.
• Condition :Over 4.7V(-90 °C)
->Immediately stops the operation showing error mark.
• Condition : The room temperature does not drop more
than 2 °C aster the compressor working more
than 10 minutes.
->Continue the normal operation.
• Condition : The communication stopped more than 90
seconds.
->Appears E5.
Treatments
• Check the voltage of room
temperature sensor and
resistance at 20 °C.
-> Voltage :2.5V
-> Resistance :20K
• Check the voltage of room
temperature sensor and
resistance at 20 °C.
-> Voltage :2.5V
-> Resistance :20K
• Check the voltage of room
temperature sensor and
resistance at 20 °C
-> Voltage :2.5V
-> Resistance :20K
• Check the voltage of room
temperature sensor and
resistance at 20 °C
-> Voltage :2.5V
-> Resistance :20K
• Check the voltage of room
temperature sensor and
resistance at 20 °C.
-> Voltage :2.5V
-> Resistance :20K
• Check the Compressor
working
• Check the micro switch
connection and any
damage.
Summary of Contents for DSA-0910LG-M
Page 2: ...FLOOR STANDING TYPE Air Conditioner Model DPA 246LR DPA 246LG...
Page 16: ...14 2 DPA 246LR LGINDOORUNITOUTLINEANDSECTION...
Page 19: ...17 1 INDOORUNIT 4 WIRING DIAGRAM...
Page 20: ...18 2 OUTDOORUNIT...
Page 22: ...20 1 DPA 246LR LGINDOORUNIT 5 EXPLODED DIAGRAM...
Page 25: ...23 2 DPA 246LR LG OUTDOOR UNIT...
Page 31: ...29 8 PCB DRIVING DESCRIPTION 1 DPA 246L R G INDOOR UNIT MAIN PCB CIRCUIT...
Page 32: ...30 2 DPA 246L R G INDOOR UNIT FRONT PCB CIRCUIT...
Page 33: ...3 DPA 246L R G OUTDOOR UNIT PCB CIRCUIT...
Page 43: ...SPLIT TYPE Air Conditioner Model DSA 0910LR M DSA 0910LG M...
Page 46: ...3 2 OUTLINE AND DIMENSIONS 1 INDOOR UNIT DSA 0910LR G M...
Page 56: ...13 4 WIRING DIAGRAM Indoor Unit DSA 0910LR G M...
Page 59: ...16 6 CONTROL BLOCK DIAGRAM DSA 0910LR G M...
Page 66: ...23 PCBDRIVINGDESCRIPTION...
Page 67: ...24 1 PCB CIRCUIT DIAGRAM DSA0910LR G M...
Page 76: ...33 3 EXPLODED DIAGRAM Indoor Unit DSA 0910LR G R...