It is often easier to draw more water than needed and adjust the depth by manually 
lifting the drain until the water level is at 0% 
 
Bath  tub  calibration  should  only  be  undertaken  when  the  bath  tub  is  in  sight,  and 
you  have  easy  access  to  the  power  switches  supplying  bathomatic  and  all 
associated  equipment.    It  is  advisable  that  calibration  is  done  prior  to  final 
positioning  of  the bath  panels/aprons.   

bathomatic  can  only  operate  reliably  if  it  is 

calibrated correctly 

100% - bath calibration 

Different  bathtubs  hold  different  amount  of  water  and  100%  calibration  is 

absolutely necessary

 to ensure correct operation.  bathomatic can take any depth 

to be 100% and you have to set it for your own bath.  This should be set at around 
20mm  below  the  point  of  overflow.   When  bathtub  is  at  100%  depth  let  the  water 
settle for 1 minute then select SET 100% in the SERVICE MENU and press 

 to 

store the value.  

Before you attempt to SET 100% you must first SET 0%

 

 

It  is  strongly  recommended  that  100%  bath calibration  is  made  below  the  point of 
overflow. 

 

If  100%  -  bath  calibration  is  set  at  the  point  of  overflowing,  due  to  the 
fluctuation  of  depth  reading  bathomatic  may  never  reach  100%,  thus  it  may 
not stop filling should 100% fill is requested.  
 

Bathomatic must be 

“PAUSED” for 0% or 100% bath calibration to take place 

Temperature Offset 

Allows the temperature reading from the bath to be offset.  Must only be performed 
by trained professionals or after consulting our technical stuff. 

Temperature Calibration 

Allows  temperature  sensor  calibration.    Must  only  be  performed  by  trained 
professionals or after consulting our technical stuff. 

Reset 

Factory reset the device to its factory settings.  All customer data including presents 
and calibration will be lost. 
 

Summary of Contents for Bathomatic Basic MK3

Page 1: ... Basic User Interface MK3 User Guide bathomatic automated bath filler and shower control These instructions are to be left with the user COPYRIGHT 2007 2016 UNIQUE AUTOMATION ...

Page 2: ...s 5 Running a preset 5 Changing a preset 6 Saving a preset 6 Hand Shower 7 Drain Operation 7 Closing the drain 7 Opening the drain 7 Main menu 8 Set Up Menu 10 Depth Calibration 10 Set Level 10 0 bath calibration 10 100 bath calibration 11 Temperature Offset 11 Temperature Calibration 11 Reset 11 Trouble Shooting 12 ...

Page 3: ...ing and water temperature maintenance leaving the pleasurable part of the bathing experience bathomatic can be controlled by a range of interfaces and this guide covers the use of the bathomatic Basic User Interface BUI Below are simple instructions allowing users to run a bath and alter their preferences using the easy to navigate BUI with its function navigation buttons and graphics display Basi...

Page 4: ... status Filling when bathomatic is filling Pause bathomatic filling draining is paused1 Draining emptying when bathomatic is draining DRAINING Empty CHOOSE TEMP DEPTH Ready READY WHEN YOU ARE Water Temperature the temperature of the water in the bath Water Depth the depth of the water in the bath Desired Temperature the temperature value last sent to bathomatic Desired Depth the depth value last s...

Page 5: ...matic is empty and is not filling or draining Should you wish to change the desired temperature and depth when bathomatic is filling or draining press which will pause bathomatic then change the values and press and hold again for bathomatic to resume filling to the new settings Presets bathomatic stores 9 presets with individual temperature depth and fragrance selection Running a preset From the ...

Page 6: ... back At any time you can run the altered preset without saving it just press which takes you back to the list of preset and press again for filling to take place Saving a preset Following the process above alter the variables of a preset and end the process by scrolling to the Store preset line and using store the preset or using store the preset and go back to the preset menu Temperature 38ºC Pr...

Page 7: ...status leaving the hand shower Non active Active Drain Operation Closing the drain BUI has a dedicate drain button When the bath is empty and the drain is open pressing the button will prompt a message CLOSE DRAIN and to do this you need to press the button Opening the drain When the bath drain is closed with an empty bath or one containing water the pressing of the button will prompt a message OP...

Page 8: ...tes AUTO PAUSE Allows auto pause when there is not enough hot water T TO DEPTH WARNING Depth to T warning When this function is ON and the device s T to depth calibration in the Service Menu has been set a warning message will appear When this function is set to OFF there will be no message but there will be no guarantee of perfect water depth and temperature delivery TEMPERATURE PRIMING With this...

Page 9: ...ave up to two auxiliary slave BUI DEVICE TYPE a system needs one master device to operate and can have up to two slave devices ABOUT Firmware version and service contact details Exit by pressing the menu button To move back a step press the menu button also Due to a delay in your hot water delivery system there are minimum bath depths for certain temperatures3 If you are prompted with a message DE...

Page 10: ...ct full bath depth is reached Filling does not stop automatically and can cause damage unless used correctly 0 bath calibration The easiest and fastest way for 0 bath calibration is by pouring water into the bath tub with the drain closed until the water fills the cavity of the waste completely and becomes level with the bottom of the bath tub When the water is level with the bottom of the bath tu...

Page 11: ...he point of overflow When bathtub is at 100 depth let the water settle for 1 minute then select SET 100 in the SERVICE MENU and press to store the value Before you attempt to SET 100 you must first SET 0 It is strongly recommended that 100 bath calibration is made below the point of overflow If 100 bath calibration is set at the point of overflowing due to the fluctuation of depth reading bathomat...

Page 12: ...c pauses on its own If the water delivered to the bath starts to decrease and the perfect bath cannot be delivered bathomatic will prompt you with WATER TEMPERATURE MAY NOT BE ACHIEVED and bathomatic will automatically go into pause Maximum water temperature during filling is 55 C ...

Reviews: