background image

 

UNIQ 

 

 

 

 
 

 

UC-610/UC-610CL

 

 Color Digital CCD Camera 

User's Manual 

 

091-0611 V.1.4 

09-23-05

 

 

 

 

 

 

 

 

       

Summary of Contents for UC-610

Page 1: ...UNIQ UC 610 UC 610CL Color Digital CCD Camera User s Manual 091 0611 V 1 4 09 23 05 ...

Page 2: ...ited Warranty 2 1 Introduction 3 2 Camera Setup 5 3 Camera Functions 5 4 RS 232C Communication Control 10 5 Digital Interface Timing 12 6 Camera Functional Timing 13 7 Camera Accessories 15 8 Camera Malfunction 16 9 Technical Support Information 17 ...

Page 3: ...ts Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or damages due to defects in material or workmanship which occur during normal use It does not cover damages or failures which result from shipment mishandling abuse misuse or modification A Return Materia...

Page 4: ...ent signal to noise performance It s compatible with most popular frame grabbers in the market The user friendly RS 232C interface control allows users to control all camera functions without physically touching the camera 1 2 Features 1 3 Progressive scan CCD imager R G B primary color mosaic filters 659 x 494 active pixels 10 bit RS 644 LVDS Camera Link output Full frame shutter 1 110 1 110 000 ...

Page 5: ...Hz Digital Video Output 10 bit RS 644 Camera Link Format Analog Video Output 1 V p p 75ohm BNC or 12 pin Hirose S N Ratio 56 dB Min Illumination 3 lux Gain MGC Gamma 1 0 Electronic Shutter 1 110 1 110 000 selectable Lens Mount C Mount Operating Temperature 10 C 50 C Power Requirement 12V DC 280 mA 3 4 W Dimension 50mm x 39mm x 83mm Ext Sync Internal External Auto Switch Asynchronous Reset Standard...

Page 6: ... grounds 12 V DC input is recommended on pin 2 but this camera should withstand 12 V 1V input voltage Make sure to set the NM AM switch to NM position for external HD and VD locking For HD pin 6 and VD pin 7 inputs TTL signals are required see section 6 6 for details For asynchronous capture VINT applications refer to section 6 for details For RS 232C interface control via this 12 pin connector us...

Page 7: ...For normal shutter speed make sure to set NM AM mode to NM location For asynchronous capture set NM AM mode to AM location Shutter Speed Select DS Position No Functional Select NS Shutter Speed sec NM Mode Asynchronous Capture sec AM Mode 0 Normal 1 110 1 110 1 Gain Adjustment 1 125 1 250 2 Reference Adjustment 1 250 1 500 3 Factory Page 1 500 1 1000 4 User Page 1 1 1000 1 2000 5 User Page 2 1 200...

Page 8: ...settings can be saved into four different user pages Once the user page is saved and set between shutter speeds 4 and 7 it will be activated as long as the camera is powered ON User Page works in both rear plate control and RS232C communication selections 3 5 Gain Control AGC MGC Note This gain potentiometer only applies to cameras without Up Down switch on rear plate Manual gain control MGC MGC i...

Page 9: ... LVDS 12 DATA2 O RS644 LVDS 32 DATA3 O RS644 LVDS 13 DATA4 O RS644 LVDS 33 DATA5 O RS644 LVDS 14 DATA4 O RS644 LVDS 34 DATA5 O RS644 LVDS 15 DATA6 O RS644 LVDS 35 DATA7 O RS644 LVDS 16 DATA6 O RS644 LVDS 36 DATA7 O RS644 LVDS 17 DATA8 O RS644 LVDS 37 DATA9 O RS644 LVDS 18 DATA8 O RS644 LVDS 38 DATA9 O RS644 LVDS 19 RESERVED 39 RESERVED 20 RESERVED 40 RESERVED Note 1 DATA9 is most significant bits ...

Page 10: ...TA3 Video LEN and FEN data output 7 20 SerTC SerTC Rx Rx Differential pair serial communications from frame grabber 8 21 SerTFG SerTFG Tx Tx Differential pair serial communications to frame grabber 9 22 CC1 CC1 HD HD Camera Control 1 CC1 Horizontal signal input 10 23 CC2 CC2 VINT VD VINT VD Camera Control 2 CC2 Vertical signal or asynchronous reset input 11 24 CC3 CC3 Reserved Reserved for custom ...

Page 11: ... uncheck the Hyper Terminal section depending if you want Hyper Terminal to be installed or uninstalled if you want to reinstall Hyper Terminal uncheck and then click ok and then repeat the above process and re check Hyper Terminal For first time user of Hyper Terminal go to Properties Select 9600 bits per second in Configure Enable Echo typed characters locally box in ASCII setup 4 2 RS232C commu...

Page 12: ...stored gain gd Gain decrease Hexadecimals 000 3ff Same as gi above except it will be decreased gn Gain number Hexadecimals 000 3ff Refer to the gain curves below for details Only one curve applies to each camera depending on camera model contact UNIQ for further details bi Reference increase bd Reference decrease bn Reference number Hexadecimals 000 3ff If no number entered reference will be incre...

Page 13: ...12 5 Digital Interface Timing 5 1 Pixel Clock 5 2 Line Enable 5 3 Frame Enable Note 1 Pixel clock 40MHz 2 1 N 25 nsec 3 1 H 718 N ...

Page 14: ...r Speed position 0 110 fps 6 2 Free Run Shutter speed position from 1 to F 6 3 Asynchronous Capture Shutter speed position 0 6 4 Asynchronous Capture shutter speed position from 1 to E 6 5 Asynchronous Capture with Pulse Width Control shutter speed F ...

Page 15: ...ure 10 External Synchronization and Gen lock Timing 6 7 Integration via 12 pin Hirose connector ONLY The UC 610 UC 610CL camera can be integrated up to 2 seconds without severe noise or dark current effect To start integration pin 11 same as pin 27 of 40 pin digital connector of the 12 pin connector must be connected to GND or 0V The integrated video will be shifted out following the next vertical...

Page 16: ...camera There are a variety of C mount lenses in the market that works with UC 610 UC 610CL camera Make sure the quality and specification of the lens match the camera s application Some of the most popular lenses in the market such as Cosmicar Fujinon Rodenstock and Schneider are recommended 7 3 Digital Connector and Cable 7 3 1 40 pin Digital Connector and Cable UNIQ stocks standard and custom ca...

Page 17: ... frame grabber setup procedures are done correctly a good image should be appeared on a display monitor f If it fails to show any good images check the interface cable pinouts both camera and frame grabber end consult UNIQ or frame grabber manufacturer if necessary Also make sure the UC 610 UC 610CL camera configuration file is correct g If problem still exits contact UNIQ or frame grabber manufac...

Page 18: ... RS 232C is via 9 pin D sub connector at PC end make sure to short or connect pin 4 and 6 and then short or connect pin 7 and 8 but do not connect all 4 pins together 9 Technical Support Information For technical assistance contact UNIQ Technical Support or Applications Engineer at Phone 408 330 0818 Fax 408 330 0886 Email tech uniqvision com Company contact information UNIQ VISION INC 3220 Scott ...

Reviews: