PUTTING INTO OPERATION
Before putting the system with TURBI-M3 control unit into
operation, it is necessary to fill the pump and suction line
with water and remove air completely. To do this, open all
valves, connect power supply and pump water into the sys-
tem as long as it flows from all valves.
OPERATION RULES FOR USE OF
SYSTEM WITH TURBI-M3 CONTROL
UNIT
1. It is necessary to comply with requirements to pumped
fluid (see Section “Specifications”).
2. Compressed air pressure in pressure tanks shall be lower
than Pmin by 0.1 - 0.2 bar. It is necessary to check it at
least once a month in accordance with Manual for Pre
sure Tank.
3. Avoid water coming to the control unit housing
4. It is not permissible to use TURBI-M3 control unit with
upper cover removed.
5. Avoid water coming into the pump suction line.
6. Avoid water freezing in the device and the system. In
winter it is necessary to drain water out of surface pump
and TURBI-M3 control unit and place them for storage.
MAINTENANCE AND STORAGE
During operation, the device requires no maintenance.
To ensure reliable operation and long service life, it is nec-
essary to meet all the requirements set forth in the present
Manual.
If the system is not used for a long time in winter, it is nec-
essary to disconnect power supply, drain water from it and
dismount TURBI-M3 control unit.
Store the device in dry and heated premises away from direct
sunlight. Permissible storage temperature: from +1 to + 40°C.
DISPOSAL
This product shall not be disposed together with household
wastes. Contact local utility services to know possible meth-
ods for this equipment disposal.