INSTRUCTION MANUAL FOR THE LD514 REMOTE DISPLAY

Rev.1.08

02 Sep. 2010

Standard

LD515

comparible

A/D converter input over

A/D converter input negarive over

Net weight

Net Over 

Total weight

Maximum scale value

+ 9 divisions

Total weight

Total quantity over

Tare quantity

99999

Loadcell Indicator

CZ

ZT

MD ZALM TARE NET GROSS

HOLD

LD514

 

EXTERNAL

 

DISPLAY

HOLD

When the indicator is in one of the following states,
this LED comes on.
- The indicated weight value is held.
- The hold signal is input in the rear panel terminal base.
- The digital indicator status is HOLD.

GROSS

When the indicated weight value is a total
weight, this LED comes on.

NET

When the indicated weight value is a net weight,
this LED comes on.

TARE

When the indicated weight value is a tare weight
or the indicator is in the tare subtraction status,
this LED comes on.

CZ

When the indicator is within 

±

1/4 scale division

from the zero point, this LED comes on to
indicate the true zero point.

ZT

When the indicator is Zero Tracking (ZT), this
LED comes on.

MD

When the indicator status is stable, this LED
comes on.  (This may come on in the unstable
status depending on the indicator type.)

ZALM

When the indicator status is Zero Alarm 
(ZALM), this LED comes on.

kg

N

t

g

Unit of weigt

The unit of weight value is none at delivery.  Select a necessary unit
indication from attached unit seals and paste it at a proper position.

lb

Negative sign indicating digit

Digital Indicator

(※

This indicator is based on the 

overflow indication of  our F360A 
series, so the indication may be 
different from  the indication of the 
LD514 main unit depending on the 
indicator that is connected.

  

A/Dconverter 

over scale

A/Dconverter over scale

Indicated value

99999

   
     

  

Connection Fault Indication

When the dedicated serial interface input short-circuits 

or wire breaking occurs, or when the rotary switch is not 
selected correctly, blanking (all digit OFF) takes place 
and all the status indicating LEDs come on.

In this case, check the following items and take a proper 

measure.

- When the dedicated serial interface is used, check if it is
   correctly connected or any wire breaking does not  
   occur.
- Check if the rotary switch is set according to the
   specified number.
- Check if the indicator is normally operated.

When the all-digit indicating part and the status 
indicating LEDs do not come on, check the following 
item and take a proper measure.

- Check if the power supply (100 to 220 V AC) is
   correctly input.

FRONT PANEL

Numeric display part

This part indicates the following 7 types of value.
- Total weight
- Net weight
- Tare weight
- Load cell indicator interrelated value (Standard mode)
- Load cell indicator interrelated value (LD151 compatible mode)
- Digital indicator interrelated value
- Over-scale indication

    

Self-check (self-diagnosis) method

The LD514 can make a self-diagnostic test by special operation 
or a command from the indicator.  If any fault is not found by 
self-diagnostic test (ROM check), a visual check is started in 
succession.  At the visual check, a decimal point and a number 
of 0 to 9 are displayed for each digit on the display unit.  
Visually check if the numeric value can be normally indicated.

The self-check is made in the following two cases.

- The power supply is turned on after the rotary switch is set to

 the self-check mode.
When the rotary switch is set to No.8 and then the power 
supply is turned on, the check is repeated until this setting on 
the rotary switch is changed.

- A self-check command is given from the indicator that is

connected.
For making a self-check, the load cell indicator such as F805
outputs a check command to the LD154.  Some types of
indicator may not output a check command.  For details, refer
to the instruction manual for the respective indicator.

      Visual check

If the indication is provided as shown above, the 

display unit is normal.