7.FUNCTION AS A WEIGHT CHECKER
56
2) SAMPLE MODE
Set the sampling width to calculate the average of the take-in interval.
Select from 100%/ 50%/ 25%/ 12.5%.
100%
The average is calculated by using all the sample data.
50%
The average is calculated by using the data 25% before and after the center
of the sample data (50% in total).
25%
The average is calculated by using the data 12.5% before and after the
center of the sample data (25% in total).
12.5%
The average is calculated by using the data 6.25% before and after the
center of the sample data (12.5% in total).
Operation
7-4-3. Gross ratio
If a fixed error occurs in weighing, make adjustment by ratio multiplication.
Normally set
“
1.000
”
(no adjustment).
(input range: 0.001 ~ 9.999)
Operation
The average of this part corresponds
to the RESULT.
◇
Example at 50%
Take-in interval
Near zero
MODE
SEQUENCE MODE
→
Press
AVERAGE MODE
→
Select ARITHMETIC/ REMOVAL
OK
→
1)
→
MODE
SEQUENCE MODE
→
Press
SAMPLE MODE
→
Select 100%/ 50%/ 25%/ 12.5%
OK
→
2)
→
MODE
SEQUENCE MODE
GROSS RATIO
→
Press
→
Input 0.001 ~ 9.999
OK
→
→