7.STATISTICAL AND ACCUMULATION FUNCTION SETTING AND OPERATION
107
7-4. Auto Accumulation Command
Select whether or not to automatically accumulate weight values in the F701-C. If the auto accumu-
lation command is on, an accumulation is made when the complete signal of the F701-C turns on.
At this time, the count, accumulation value and statistical data are updated, and also an auto print
command is sent onto the SI/F format.
However, in the case where the result of weighing is negative or in the case of “over scale”, no
accumulation is made if no judgment is set.
Auto accumulation command timing
1) Simple comparison command
0
Near Zero
Final
-
Setpoint 1
Final
-
Setpoint 2
Final
-
CPS
Final
Weighing Value
over
under
Time
Near Zero
SP1
SP2
SP3
Judging Time
Stable
Complete
OFF
ON
ON
ON
ON
ON
t2
ON
ON
Accumulation
t2 : Judging time