6.FUNCTIONS
57
6-5. Motion Detection
Set the parameters for detecting stability.
When the condition of the weight value, varying under the preset range, continues for the preset
time or more, the weight value is regarded as stable, and the STAB status turns ON.
At each time of A/D conversion, D in the following figure and the range are compared, and if
the preset range is exceeded, the STAB status turns OFF.
* D is the difference between the present weight value and 100msec.-old weight value.
Weight
100ms
10ms
D
Setting range
Period / 0.0 to 9.9
Initial value / 1.5
Range / 0 to 99
Initial value / 10
value
Summary of Contents for F156
Page 1: ...F156 WEIGHING CONTROLLER 07 JUN 2012 REV 1 40 OPERATION MANUAL CC Link Ver 1 10...
Page 115: ...7 REMOTE CONSOLE UNIT 106 Monitor change Change the display with the key...
Page 120: ...7 REMOTE CONSOLE UNIT 111 Monitor change Change the display with the keys 0 to 9 1 2 3 4 5 0...
Page 155: ...13 DIMENSIONS 146 13 DIMENSIONS...