INV2500-HS & INV5000-HS SERIES

OPERATING MANUAL

4.3

When operating these inverters, the chassis ground terminal must be con-
nected to safety ground to minimize electrical shock hazard and to ensure low
EMI (electromagnetic interference).

4.4

The internal voltages are at hazardous potentials.  The inverter covers should
not be removed.  There are no user-serviceable components in these units.
Removing the covers of the inverters will void the warranty.

5.0

WARRANTY

All products of UNIPOWER Telecom, a division of UNIPOWER Corporation, are warranted for
two (2) years from date of shipment against defects in material and workmanship.  This warranty
does not extend to products which have been opened, altered or repaired by persons other than
persons authorized by the manufacturer or to products which become defective due to acts of
God, negligence or the failure of customer to fully follow instructions with respect to installation,
application or maintenance.  This warranty is extended directly by the manufacturer to the buyer
and is the sole warranty applicable.  EXCEPT FOR THE FOREGOING EXPRESS WARRANTY,
THE MANUFACTURER MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR PURPOSE.  As the sole and exclusive remedy under this warranty, the manufacturer, at its
option, may repair or replace the non-conforming product or issue credit, provided the
manufacturer’s inspection establishes the existence of a defect.  To exercise this remedy, the
buyer must contact the manufacturer’s Customer Service Department to obtain a Return Material
Authorization number and shipping instructions.  Products returned without prior authorization
will be returned to buyer.  All products returned for repair must be shipped freight prepaid to
UNIPOWER.  If the buyer fails to fully comply with the foregoing, the buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost
sales, injury to person or property or any other incidental or consequential losses) shall be
available to the buyer.

6.0

UNPACKING AND INSPECTION

6.1

This INV2500-HS or INV5000-HS was carefully tested, inspected and pack-
aged for shipment from our factory.  Upon receipt of the unit, it should be
carefully unpacked and inspected for any damage in shipment.

6.2

If there is evidence of damage, do not attempt to test the unit.  The freight
carrier should be notified immediately and a claim for the cost of the inverter
should be filed with the carrier for direct reimbursement.  Be sure to include
the model and serial number of the damaged unit in all correspondence with
the freight carrier.  Also save the shipping carton and packing material as
evidence of damage for the freight carrier’s inspection.

6.3

UNIPOWER Telecom will cooperate fully in case of any shipping damage
investigation.

Summary of Contents for INV2500-HS

Page 1: ...UNIPOWER Telecom Division of UNIPOWER Corporation 09 4 02 INV2500HS 5000HS Man Rev3 NORTH AMERICA 3900 Coral Ridge Drive Coral Springs Florida 33065 USA Tel 1 954 346 2442 Fax 1 954 340 7901 sales un...

Page 2: ...on of Operation 5 8 0 Front and Back Panel Descriptions 5 9 0 Electrical Specifications 7 10 0 Mechanical Dimensions of Shelves 8 11 0 Safety and Industry Standards 8 12 0 Operating Information 10 13...

Page 3: ...echanical Dimensions of INV5000 HS INVR2U HS Shelves 9 5 INV2500 HS Inverter Output Waveforms 11 6 INV2500 HS INV5000 HS Overload Characteristic 12 7 Connections for ORing Form C Relay Outputs on INV5...

Page 4: ...its connected in series in their shelf to give the higher voltage See the product line designa tion in Section 3 0 The output is 230VAC at 22 amperes or 5 000 volt amperes 1 4 The 48VDC nominal input...

Page 5: ...2 INV2500 HS INV5000 HS SERIES OPERATING MANUAL a INV2500 HS Inverter Module b INV5000 HS Inverter System Figure 1 INV2500 HS and INV5000 HS Inverter Models...

Page 6: ...3 1 Telecom Hot Swap Inverter Modules Table 3 2 Hot Swap Inverter Shelf Table 3 3 230VAC Inverter Systems 4 0 SAFETY WARNINGS 4 1 These telecom inverters have hazardous external and internal voltages...

Page 7: ...option may repair or replace the non conforming product or issue credit provided the manufacturer s inspection establishes the existence of a defect To exercise this remedy the buyer must contact the...

Page 8: ...t in that their outputs are 180o out of phase with each other 7 3 Two INV2500 HS inverter modules in an INVR2U HS shelf are connected in parallel in the shelf and become an inverter system with a 115V...

Page 9: ...HS Module 18 32 465 3 46 87 9 Figure 3 Front and Back of INV5000 HS System INV5000 HS FRONT VIEW INV5000 HS BACK VIEW A SIDE B SIDE INV2500 HS BACK VIEW INV2500 HS FRONT VIEW 8 50 216 3 32 84 3 HOT SW...

Page 10: ...input full load and 25 C unless otherwise noted Asterisk means specification is same as center column INPUT Voltage Range 42 56 VDC Input Current Full Load 48VDC 60A DC 120ADC 120ADC Input Current No...

Page 11: ...NS OF SHELVES Figure 4 shows the mechanical dimensions for the INVR2U HS and INV5000 HS shelves The shelves are identical at 16 38 inches 416mm deep with the rear plastic cover they are 18 00 inches 4...

Page 12: ...9 INV2500 HS INV5000 HS SERIES OPERATING MANUAL 18 32 465 3 46 87 9 Figure 4 Mechanical Dimensions of INV5000 HS INVR2U HS Shelves 17 38 441...

Page 13: ...volt amperes Exceeding these values may cause electronic shutdown of the output Full output power is produced at up to 50o C ambient temperature Above this output current must be derated at 2 5 o C M...

Page 14: ...000 HS SERIES OPERATING MANUAL Figure 5 INV2500 HS Inverter Output Waveforms a Full Load Step Vo top Io bot 20A cm c Short Circuit Applied Vo top Io bot 50A cm 1 2 1 2 1 2 b Sudden Overload Applied Vo...

Page 15: ...NV5000 HS Overload Characteristic 0 10 20 30 40 50 60 70 80 0 20 40 60 80 100 120 140 160 INV2500 HS or 230VAC INV5000 HS 2 INV2500 HS IN INVR2U HS Figure 7 Connections for ORing Form C Relay Outputs...

Page 16: ...give an OR function for either set of contacts 12 8 Sync Connections There are Sync and Sync terminals on the terminal block When two or more inverters are connected in parallel these Sync terminals...

Page 17: ...ins 14 18 J1 3 2 1 6 5 4 9 8 7 11 10 13 12 15 14 17 16 19 18 21 20 24 23 22 27 26 25 30 29 28 33 32 31 PIN FUNCTION 1 AC Line 2 NC 3 AC Line 4 NC 5 AC Neutral 6 NC 7 AC Ground 8 AC Neutral 9 NC 10 NC...

Page 18: ...at 115VAC The AC output is distributed by a DPAC1UT AC Distribution Panel made by UNIP OWER Telecom Note that only 115VAC inverters can be used with the DPAC1UT distribution panel and not the 230VAC...

Page 19: ...16 INV2500 HS INV5000 HS SERIES OPERATING MANUAL Figure 9 Two 115VAC INVR2U HSs in Parallel Using AC Distribution Panel Figure 10 Output Connections for Inverters AC OUTPUTS INVR2U HS INV5000 HS 230...

Page 20: ...AC output breaker Check the AC voltage across the load with a digital AC voltmeter The voltage should be between 115 and 120VAC or between 230 and 240VAC depend ing on the model 14 6 Check the Form C...

Page 21: ...actory due to the complexity of the series connection of the inverter modules 16 3 When the INV2500 HS inverters are operated in a N 1 redundant mode only the inverter module being replaced needs to b...

Page 22: ...Telecom at 954 346 2442 Ext 400 for help Input OK LED does Bad connection to input Check the connection to battery check not come on battery input breaker not battery voltage check that input breaker...

Reviews: