Edition 3.5.17 |
Product design and technical data may be subject to change
Cable can enter the luminaire via the side entry or rear entry as
shown in the figure below. Ensure both entries are sealed by either
the seal nut or gland (items are interchangeable between rear and
side entries), thus ensuring a complete seal of the luminaire and the
integrity of the IP rating is not affected. If the gland or seal nut is
not used, please ensure the luminaire maintains its stated IP rating.
FOR WARRANTY INFORMATION VISIT
UNIOS.COM/WARRANTY
Please read these installation instructions carefully before installing this luminaire. The luminaire is designed for installation in accordance with relevant
Australian Standards (AS/NSZ 3000). Installation of this luminaire must comply with local and national regulations. If luminaire is not installed
according to the instructions, the warranty for the luminaire may be void.
ENQUIRIES
+61 8 9248 1888
Page
2/2
unios.com
Accessories
Wiring
Dimming
Corrosion Protection
Cleaning
Side and Rear Cable Entry
4x Anchor
Plugs
Included
Additional
4x Phillips
Screws
2x Mounting
Plate
Before cleaning, disconnect from mains supply and
allow luminaire to cool.
Regular cleaning of the luminaire is
strongly recommended
. In harsher
conditions, it is recommended that a strict cleaning schedule is in place
to ensure no eroding chemicals are left on the surface for long periods.
To clean luminaire, only use a damp, microfibre cloth. A dilute solution of
a mild pH-neutral liquid detergent can be used for resistant dirt
(Solvents must not be used). Please note surface of luminaire must be
wiped down with a clean damp microfibre cloth to ensure no residue is
left on the surface. Take care not to damage the surface of the
luminaire. Do not use high pressure cleaners.
It is important to note that care must be taken during
installation or maintenance to ensure that the surface of
the luminaire is not damaged. Any damage, which is
exposed to moisture will result in corrosion occurring.
Please also note that any chemical applications on the luminaire will
cause corrosion of the surface of the luminaire and will void the warranty.
This luminaire can not be dimmed.
Specific DALI option available.
This luminaire must be installed in conjunction with
electronic control gear (Built-in).
2x Suspension Kit
(2m steel cable)
60
.1
36.8
83.6
42
M20
Class I
Luminaire in which protection
against electric shock does not
rely on basic insulation only,
but which requires conductive
parts to be connected a
protective earthing conductor.
Protected against dust
completely and Jets of water
from all directions.
220-240V 50-60hz AC Supply.
This luminaire is suitable for
outdoor use, taking in
consideration of the IP rating.
IP65
A luminaire that can
withstand impact
acquivalent to 1.7kg of mass
dropped 300mm above
surface. Protected against 5
joules impact.
IK08
AC