background image

Edition 3.5.17 | 

Product design and technical data may be subject to change

Cable can enter the luminaire via the side entry or rear entry as 
shown in the figure below. Ensure both entries are sealed by either 
the seal nut or gland (items are interchangeable between rear and 
side entries), thus ensuring a complete seal of the luminaire and the 
integrity of the IP rating is not affected. If the gland or seal nut is 
not used, please ensure the luminaire maintains its stated IP rating.

FOR WARRANTY INFORMATION VISIT 

UNIOS.COM/WARRANTY

Please read these installation instructions carefully before installing this luminaire. The luminaire is designed for installation in accordance with relevant 

Australian Standards (AS/NSZ 3000). Installation of this luminaire must comply with local and national regulations. If luminaire is not installed 

according to the instructions, the warranty for the luminaire may be void.

ENQUIRIES

+61 8 9248 1888

[email protected]

Page 

2/2

unios.com

Accessories

Wiring

Dimming

Corrosion Protection

Cleaning

Side and Rear Cable Entry

4x Anchor 

Plugs

Included

Additional

4x Phillips 

Screws

2x Mounting 

Plate

Before cleaning, disconnect from mains supply and 
allow luminaire to cool.

Regular cleaning of the luminaire is 

strongly recommended

. In harsher 

conditions, it is recommended that a strict cleaning schedule is in place 
to ensure no eroding chemicals are left on the surface for long periods. 
To clean luminaire, only use a damp, microfibre cloth. A dilute solution of 
a mild pH-neutral liquid detergent can be used for resistant dirt 
(Solvents must not be used). Please note surface of luminaire must be 
wiped down with a clean damp microfibre cloth to ensure no residue is 
left on the surface. Take care not to damage the surface of the 
luminaire. Do not use high pressure cleaners.

It is important to note that care must be taken during 
installation or maintenance to ensure that the surface of 
the luminaire is not damaged. Any damage, which is 
exposed to moisture will result in corrosion occurring. 

Please also note that any chemical applications on the luminaire will 
cause corrosion of the surface of the luminaire and will void the warranty.

This luminaire can not be dimmed. 
Specific DALI option available.

This luminaire must be installed in conjunction with  
electronic control gear (Built-in).

2x Suspension Kit

(2m steel cable)

60

.1

36.8

83.6

42

M20

Class I

Luminaire in which protection 

against electric shock does not 

rely on basic insulation only, 

but which requires conductive 

parts to be connected a 

protective earthing conductor.

Protected against dust 

completely and Jets of water 

from all directions.

220-240V 50-60hz AC Supply.

This luminaire is suitable for 

outdoor use, taking in 

consideration of the IP rating.

IP65

A luminaire that can 
withstand impact 
acquivalent to 1.7kg of mass 
dropped 300mm above 
surface. Protected against 5 
joules impact.

IK08

AC

Outdoor Use

Reviews: