FOR WARRANTY INFORMATION VISIT
UNIOS.COM/WARRANTY
Please read these installation instructions carefully before installing this luminaire. The luminaire is designed for installation in accordance with relevant
Australian Standards (AS/NSZ 3000). Installation of this luminaire must comply with local regulations. If luminaire is not installed according to the
instructions, the warranty for the luminaire may be void.
ENQUIRIES
+61 8 9248 1888
Edition 3.5.17 |
Product design and technical data may be subject to change
Exon R08
LINEAR LIGHT
Power
20/40 Watts
Material
Aluminium
Warranty
5 Years
IP Rating
65
unios.com
Class I
220–240V ~ 50/60Hz
CAUTION
– Must Be Installed By A Licensed Electrician
Please read instruction manual on
both
sides carefully before installing luminaire.
• This luminaire is void of warranty if any part has been modified.
Please visit unios.com/warranty for more information.
• Over-voltage protection units should be installed to prevent electronic
control gear from failing due to electrical spikes, e.g. from switching of
inductive loads.
• Please read instructions for installation of luminaire provided below.
Safety of this luminaire and warranty will be voided unless followed.
• Please note, no external cable is provided.
• Installation and operation of this luminaire must be within
accordance with national safety regulations. Unios™ does not warrant
any liability when damage is caused by misuse or improper installation.
1
Installation Instructions
Ceiling Mounted
3
L
E
N
2
Must be installed by a Licensed Electrician.
Before installing, make sure the power supply is switched off.
Follow the steps in the figure shown for installation:
A. Mark out holes for bracket installation.
B. Install mounting brackets (or steel suspension cables) on ceiling.
C. Remove endcap which houses the gland and slide out terminal
block tray.
D.
For side cable entry
D1. Install mains cable in gland and terminate at the
terminal block.
For rear cable entry
D2. Remove seal nut and replace with side entry gland.
D3. Install seal nut in side entry end cap.
D4. Install mains cable in gland and terminate at the
terminal block.
E. Clip luminaire onto brackets.
For suspension cable installation, screw the suspension cable
fixing into rear of mounting bracket.
Note: Termination of wiring and installation of the product shall be
conducted such that the luminaire’s stated IP rating is not
affected.
Suspended
Step C: Terminal Block Tray
L
E
N
Step C: Terminal Block Tray