background image

11

 

Master Sec on

 

EQ/Isolator 

  The EQ/isolator with variable crossover control is 

designed  to  complement  the  channel  EQ  and  allow  for  some  highly 
crea ve sound sculpturing.

  

It has a fixed “Q” of 1 and can be swept 

from  150Hz  to  1kHz  (Low

-

Mid  crossover  point)  by  adjus ng  the  “X

-

over freq” control. The EQ/Isolator offers full signal cut and +6dB of 
boost  over  three  frequency  bands,  High,  Mid,  Low.  Like  an  EQ  the 
Isolator can be used for audio frequency correc on, however,  unlike 
an EQ the Isolator  completely a enuates the signal when the  knobs 
are fully an

-

clockwise. With the knob pointers in the centre posi on 

the frequency response is flat.

 

 

 

 

 

 

 

Master 

  

The  Master  Output  level  is  adjusted  from  fully  off  to 

+10dBu gain. For best signal to  noise ra o (SNR)  it  is recommended 
opera ng the mixer with the knob pointer at “12 o

-

clock” or above.  If 

this  results  in  excessive  volume  then  reduce  the  gain  on  the 
connected power amplifiers

 

Booth 

  

Adjusts the signal level of the Booth Outputs from off to 

+10dBu  when  rotated  fully  clockwise.    For  best  signal  to  noise  ra o 
(SNR),  set  the  level  with  the  pointer  at  or  above  the  12  o’clock 
posi on.

 

Phones 

  

Adjusts the level of the headphone output. The elara.4 

is fi ed with a powerful headphone amplifier, op mised for use with 
headphones  having  an  impedance  between  33ohms  to  170ohms. 
Headphones  with  impedances  above  or  below  the  recommended 
impedance  should  be  avoided,  and  in  par cular  headphones  with 
impedances below 33ohms could cause damage to the circuitry.

 

 

WARNING!  Avoid  opera ng  the  mixer  with  headphones  at 
high  volume  or  for  extended  periods  of  me  as  this  can 
contribute to severe hearing loss!

 

Summary of Contents for elara.4

Page 1: ...1 PRODUCT USER GUIDE...

Page 2: ...o make any changes deemed necessary This product has been designed to comply with the applicable standards regula ons and direc ves for the countries where the product is marketed NOTE Changes or modi...

Page 3: ...y of this product Condi ons of Warranty The equipment has not been subject to misuse either intended or accidental neglect or altera on other than approved by Union Audio The warranty does not cover p...

Page 4: ...t connect the output of ampli ers to this apparatus Always use the correct high quality cables to connect the mixer to audio sources and power ampli er inputs Do not install the mixer or power supply...

Page 5: ...ve the apparatus una ended for long periods when powered on Safety Instruc ons These symbols are interna onally accepted symbols to warn of poten al hazards with electrical products This symbol indica...

Page 6: ...4 5 Index 6 About the Elara 4 7 Front and Rear Line Drawing 8 Input Channel Controls 9 10 Master Sec on 11 12 Rear Panel Input Connec ons 13 Master Output Connec ons 14 Applica on Diagram 15 Block Dia...

Page 7: ...eo 10 LED VU meter showing pre Master mix buss level Selec ng any Cue automa cally switches the Main VU to show the channel pre fader level or channel pre fader and Mix when the split control is ac ve...

Page 8: ...8...

Page 9: ...tc Trim Controls the level of the input signal from fully OFF to a maximum gain of 10dBu Use in conjunc on with the Channel VU Meter to set the op mum signal level with the average ligh ng the Blue 0V...

Page 10: ...ch press Each channel cue is independent and will not be overridden when pressing other channel cue bu ons Meter Each channel has its own associated 10 bar LED meter The meter is peak reading and is s...

Page 11: ...best signal to noise ra o SNR it is recommended opera ng the mixer with the knob pointer at 12 o clock or above If this results in excessive volume then reduce the gain on the connected power ampli er...

Page 12: ...r Use the channel toggle switches to assign each channel to either the X or Y side of the crossfader or OFF if the switch is in the centre posi on Master Meters The Master Meters display Mix Buss leve...

Page 13: ...ing Cold and Sleeve Ground The nominal output level is 0dBu Aux Return Insert The Auxiliary Return is via a pair of 1 4 TRS Jack sockets following the standard conven on of Tip Hot Ring Signal Ground...

Page 14: ...e Master Level control is fully clockwise with the Meters reading 4VU the output level is approximately 6dBu Booth Out The Booth Output is via a TRS jacks When the Booth level control is fully clockwi...

Page 15: ...15...

Page 16: ...16...

Page 17: ...Hz Un Weighted Residual Mix Output noise 98dBu Line In to Mix Out Unity 81dBu Maximum Output Level Mix Out 0 5 THD 27dBu Dynamic Range 108dB EQ and Filter Frequency Channel High Pass Filter Fully Cloc...

Page 18: ...18 Dimensions Mixer Height 283mm Width 230mm Depth 88mm Weight 3 25kg Packed Dimensions Size L x W x H 37cm x 36cm x 19cm Weight 4 85kg 11lb Dimensions...

Page 19: ...19...