KOOLZONE MANUFACTURER’S 

RECOMMENDATIONS

12 

AWG

MAX

12FT

1. USE A DEDICATED OUTLET. DO NOT SHARE AN OUTLET WITH OTHER DEVICES. 

SHARING AN OUTLET MAY CAUSE A POWER OUTAGE.

2. IF USING AN EXTENSION CORD, A 12 AWG IS RECOMMENDED.

3. DO NOT BLOCK THE HEAT EXHAUST DUCT. 

BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT

 TO OVERHEAT AND STOP WORKING PROPERLY.

4. FOR OPTIMUM PERFORMANCE, USE ONLY UP TO A MAXIMUM OF 

12 FT OF HEAT/COOL EXTENSION DUCT.

Summary of Contents for KOOLZONE SAC-25FC

Page 1: ...USER MANUAL SAC 25FC KOOLZONE MOBILE SPOT COOLER FOR MORE INFO...

Page 2: ...KOOLZONE 2 THANK YOU FOR PURCHASING THE KOOLZONE MOBILE SPOT COOLER PLEASE READ THE INSTRUCTIONS BEFORE USING KEEP THESE INSTRUCTIONS FOR REFERENCE...

Page 3: ...NTS 1 SAFETY PRECAUTIONS PAGE 4 5 2 SPECIFICATIONS PAGE 6 3 ACCESSORIES PAGE 6 4 PARTS OF THE MACHINE PAGE 7 5 INSTALLATION PAGE 7 6 OPERATING INSTRUCTION PAGE 9 7 MAINTENANCE AND INSPECTION PAGE 10 8...

Page 4: ...r gasoline kerosene LPG aluminum magnesium and plumbum They could cause possible fire or explosion Only a professional repair service should disassemble the unit in order to avoid warranty voidance or...

Page 5: ...ge from 64 F to 104 F otherwise it may cause the unit to slow the air flow or shutdown To prevent an accident or damage the unit can not be used in the following locations Not grounded Unlevel ground...

Page 6: ...CHARGE FAN PROTECTOR CONDENSATE WATER HANDLING METHOD SIZE WEIGHT OPERATING TEMPERATURE LIMIT Single phase 115 V 60 Hz Fan 1 7 A 195 W Aircondition 8 58 A 937 W 9 210 BTU Fully Closed Type Rotary R410...

Page 7: ...STALLING THE COOLING DUCT There are two cold air outlets Both outlets can be used together one cooling duct included Additional ducts can be purchased seperately The cold air vent socket is fixed to t...

Page 8: ...r can be drained directly from the unit using the drain hose INSTALLING THE THE SWITCH CONTROL BOX The switch control box hook is attached to the side of the unit as illustrated below Connect the swit...

Page 9: ...ween 77 F to 113 F If you use the unit out of the temperature range it may not work properly Do not overload the electrical system by using too many devices off one outlet NOTIFICATION KOOLZONE 9 When...

Page 10: ...f the unit do not use abrasive materials or chemicals which could damage the unit surface Please clean the filter regularly NOTIFICATION In order to prevent accidents the unit should be placed on leve...

Page 11: ...n pipe Clean the filter Remove drain cap and empty the water Clean the condensor surface and vents Check fan Move to more a suitable place to use Check the capacitor to the compressor Check pipeline s...

Page 12: ...OTHER DEVICES SHARING AN OUTLET MAY CAUSE A POWER OUTAGE 2 IF USING AN EXTENSION CORD A 12 AWG IS RECOMMENDED 3 DO NOT BLOCK THE HEAT EXHAUST DUCT BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT TO OV...

Page 13: ...PLEASE NOTE OPTIMUM OPERATING TEMPERATURE RANGE FOR KOOLZONE MOBILE SPOT A C COOLER IS FROM 77 113 FAHRENHEIT WHEN USING THIS UNIT ON COOLING MODE THE AMBIENT TEMPERATURE WILL BE REDUCED BETWEEN 10 15...

Page 14: ...X EXCLUSIVELY DISTRIBUTED BY UNINEX INTERNATIONAL 5780 SMITHWAY STREET COMMERCE CA 90040 T 800 864 3288 323 890 9246 F 323 890 9249 MANUFACTURE NAKATOMI CO LTD 6445 2 TAKAI TAKAYAMA KAMITAKAI NAGANO J...

Reviews: