UNINEX Koolzone SAC-2500C User Manual Download Page 13

KOOLZONE

13

Evaporator Filter Screen

Condenser Filter Screen

Top

Front

Direction 

above 

16”

Direction 

above 

16”

Direction 

above 

16”

Direction 

above 

16”

Evaporator Filter Screen

Condenser Filter Screen

7. MAINTENANCE AND INSPECTION 

• When cleaning filter with heavy use, consider vacumming filter before rinsing. Rinse with water and dry 
   thoroughly before reuse.
• When cleaning the surface of the unit, do not use abrasive materials or chemicals which could damage 
   the unit surface.

Please clean the filter regularly.

NOTIFICATION

   In order to prevent accidents, the unit should be placed on level ground. Unlevel ground, stairs, 
   emergency exits should not be used. Minimum distance needed is 12” from any wall.
   While the unit operates, please do not place obstructions in front of the filter, cooling, or heating 
   exhaust duct.

 

KEEP DISTANCE

   Make sure the unit has minimum distance from any wall, ceiling, or object as illustrated below.

Summary of Contents for Koolzone SAC-2500C

Page 1: ...USER MANUAL SAC 25OOC KOOLZONE MOBILE SPOT COOLER FOR MORE INFO...

Page 2: ...KOOLZONE 2 THANK YOU FOR PURCHASING THE KOOLZONE MOBILE SPOT COOLER PLEASE READ THE INSTRUCTIONS BEFORE USING KEEP THESE INSTRUCTIONS FOR REFERENCE...

Page 3: ...Y PRECAUTIONS PAGE 4 5 2 SPECIFICATIONS PAGE 6 3 ACCESSORIES PAGE 6 4 PARTS OF THE MACHINE PAGE 7 5 INSTALLATION PAGE 7 6 OPERATING INSTRUCTION PAGE 12 7 MAINTENANCE AND INSPECTION PAGE 13 8 TROUBLESH...

Page 4: ...r gasoline kerosene LPG aluminum magnesium and plumbum They could cause possible fire or explosion Only a professional repair service should disassemble the unit in order to avoid warranty voidance or...

Page 5: ...ge from 64 F to 104 F otherwise it may cause the unit to slow the air flow or shutdown To prevent an accident or damage the unit can not be used in the following locations Not grounded Unlevel ground...

Page 6: ...REFRIGERANT RATED CHARGE FAN PROTECTOR CONDENSATE WATER HANDLING METHOD SIZE WEIGHT OPERATING TEMPERATURE LIMIT Single phase 115 V 60 Hz Fan 1 7 A 195 W Aircondition 8 58 A 937 W 9 210 BTU Fully Close...

Page 7: ...l three outlets can be used together one cooling duct included Additional ducts can be purchased seperately Select the direction of the cold air outlet needed for use The cold air vent socket is fixed...

Page 8: ...ne with the mounting bracket Using the four M8x25 screws included secure the mounting brackets Differnt Mounting Option Outside Differnt Mounting Option Inside Cold Air Flow Bottom View When installin...

Page 9: ...ng the unit on the ceiling using lifting or hoist rings Load direction of the lifting rings The flat sides of the upper and lower lifting rings should be on the same direction as shown in the diagram...

Page 10: ...a boom INSTALLATION OPTION 4 Hardware is not included Installing the unit on the table or bed Nut Nut Nut Installing Board Note Included Flat Washer Flat Washer Flat Washer Flat Washer Boom M8 Bolt M...

Page 11: ...er can be drained directly from the unit using the drain hose INSTALLING THE THE SWITCH CONTROL BOX The switch control box hook is attached to the side of the unit as illustrated below Connect the swi...

Page 12: ...ture is between 77 F to 113 F If you use the unit out of the temperature range it may not work properly Do not overload the electrical system by using too many devices off one outlet NOTIFICATION When...

Page 13: ...en cleaning the surface of the unit do not use abrasive materials or chemicals which could damage the unit surface Please clean the filter regularly NOTIFICATION In order to prevent accidents the unit...

Page 14: ...n pipe Clean the filter Remove drain cap and empty the water Clean the condensor surface and vents Check fan Move to more a suitable place to use Check the capacitor to the compressor Check pipeline s...

Page 15: ...OTHER DEVICES SHARING AN OUTLET MAY CAUSE A POWER OUTAGE 2 IF USING AN EXTENSION CORD A 12 AWG IS RECOMMENDED 3 DO NOT BLOCK THE HEAT EXHAUST DUCT BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT TO OV...

Page 16: ...PLEASE NOTE OPTIMUM OPERATING TEMPERATURE RANGE FOR KOOLZONE MOBILE SPOT A C COOLER IS FROM 77 113 FAHRENHEIT WHEN USING THIS UNIT ON COOLING MODE THE AMBIENT TEMPERATURE WILL BE REDUCED BETWEEN 10 15...