6.6.12 Object 200Eh: In-position mode
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
200Eh
0
In-
position
mode
U8
RW
Yes
No
0
∼
1
0
This Object sets operation mode of In-position.
In Profile Position Mode, if the position deviation from the target position is within the set
value (Position Window) after the position command pulse is completed, it is judged that the
positioning is completed (Target Reached).
Figure 6-2: Target reached status changes according to In-position Mode.
Information
This object can NOT be set while it is in
’Operation Enabled’ state. Please set after
’Operation Disable’.
Please refer to
4.1 Drive Status Control.
6.6.13 Object 200Fh: Encoder filter time
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
200Fh
0
Encoder
filter
time
U8
RW
Yes
No
0
∼
3
0
This object can set the Filter to the Encoder input that is input to the controller.