95/108
Information
This object can NOT be set while it is in
’Operation Enabled’ state. Please set after
’Operation Disable’.
Please refer to
4.1 Drive Status Control.
6.6.7 Object 2008h: Boost current
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
2008h
0
Boost
current U8
RW
Yes
No
0
∼
7
0
This Object sets Boost current of Motor. Boost current is a setting that improves the
acceleration characteristics by increasing the current supplied to the motor in case the
acceleration time cannot be set sufficiently. Boost current only applies to acceleration.
Boost current = Value × 50 [%]
Information
The control current is limited to 4.4 A same as Run current. Therefore, a motor (56 mm)
that rated current value exceeds 2.7 A will not increase as much as the set value even if
the set value is raised.
Information
This object can NOT be set while it is in
’Operation Enabled’ state. Please set aft
er
’Operation Disable’.
Please refer to
4.1 Drive Status Control.
6.6.8 Object 2009h: Stop current
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
2009h
0
Stop
current
U8
RW
Yes
No
2
∼
10
5
This Object sets Stop current of Motor. Unit is % and proportional to the value of Run current.
Stop current means that the current of the motor which is set automatically after 0.1 seconds
after the motor stops running. This setting can be used to reduce heat when the motor is
stopped for a long time. Please be careful that the temperature of the motor may rise if it is
set more than 60 %.
Stop current = Value × 10 [%]
Information
This object can NOT be set while it is in
’Operation Enabled’ state. Please set after
’Operation Disable’.
Please refer to
4.1 Drive Status Control.