91/108
Table 6-27: Definition of Input Value.
Value
Definition
0
1
Input goes OFF
Input goes ON
6.5.43 Object 60FEh: Digital outputs
Index Sub
Index
Name
Type Access SAVE PDO
Mapping
Value
Range
Default
Value
60FEh 0
Number of
entries
U8
RO
No
No
2
1
Physical
outputs
U32 RW
No
Rx PDO
0000 0000h
2
Bit mask
U32 RW
No
No
003F 0000h
Able to control the User output through this Object and Brake.
Table 6-28: Definition of Physical outputs and Bit mask.
Bit
Name
0
Set Brake
1
∼
15
16
Reserved
User Output 1
17
User Output 2
18
User Output 3
19
User Output 4
20
User Output 5
21
22
∼
31
User Output 6
Reserved
6.5.43.1
Set Brake
Bit 0: Set Brake controls Brake output signal. Able to manually control Brake as set the value
of Bit mask as 1.
Table 6-28: Set Brake.
Value Bit mask
Physical outputs
0
Brake Release (ON)
1
Brake Manual
Control
Brake Engage (OFF)
Information
Under Operation enabled status, Brake always released (ON). Even set Bit mask as 1 and
Physical output as 1, set values are ignored and Brake released.