6.6.24 Object 2030h: Advanced settings
Index
Sub
Index
Name
Type Access SAVE PDO
Mapping
Value
Range
Default
Value
2030h 0
Number of
entries
U8
RO
No
No
3
1
Automatic
recovery from
communication
error
U8
RW
Yes
No
0
∼
1
0
2
Disable
Automatic
transition 2
U8
RW
Yes
No
0
∼
1
0
3
Config Internal
Limit Active bit U8
RW
Yes
No
0
∼
1
0
6.6.24.1
Automatic Recovery from Communication Error
This
object can set ’EtherCAT communication error (0x7500)’ to be clear when EtherCAT
communication status is activated again. If the value is set to 1,
the ’EtherCAT
communication error (0x7500)’ is
automatically cleared the state of EtherCAT State Machine
changes from SAFE-OP to OP.
6.6.24.2
Disable Automatic transition 2
This object can set whether ’Transition 2’ of Drive State Machine occurs automatically or no
t.
If the value is set to 1, Transition 2 will not occur automatically, but rather through the
’Shutdown’ co
mmand.
6.6.24.3
Config Internal Limit Active bit
This object can change how to operate Status word bit 11: Internal Limit Active. If the value
is set to 1, the Internal Limit Active bit also displays the H/W Limit Switch status.