101/108
6.6.18.2
Pull back distance
The motor can be pulled back a certain distance when the Push Motion is finished. The
position where the motor pulls back is the position added from Position actual value by Pull
back distance (in the opposite direction to the Push Motion). The unit is pulse.
6.6.19 Object 2018h: Internal Current Value
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
2018h
0
Internal
Current
Value
U16
RO
No
Tx PDO
0
This Object displays the Torque value in the Drive. The unit of the value is mA.
6.6.20 Object 201Bh: Limit Deceleration
This object sets deceleration ratio applied in deceleration stop in Cyclic Synchronous
Position Mode.
Index
Sub
Index Name
Type Access SAVE
PDO
Mapping Value Range
Default
Value
201Bh
0
Limit
Decelera
tion
U32 RW
Yes
No
1000
∼
10e8
10e5
Unit is speed of increasing per second [pulse/s
2
].
6.6.21 Object 2020h: Error code history setting
Index Sub
Index
Name
Type Access
SAVE PDO
Mapping
Value Range Default
Value
2020h 0
Number
of
entries
U8
RO
No
No
3
1
Function U32
RW
No
No
0
2
Interval
for same
Error
Code
U32
RW
Yes
No
0
∼
3600000
0
3
Interval
for last
Error
Code
U32
RW
Yes
No
0
∼
3600000
0
This object can delete the record of Error code history or adjust the recording time.