18
11. MARKING EXPLANATION
Powered filtering device:
Australian/New Zealand standard AS/NZS 1716:2012 Respiratory protective devices-
Powered filtering devices incorporating a helmet or hood – Requirements, testing, marking
PAPR-P2 classification of the unit. “P2” defines the level of protection“P”=Particle filter.
Size
(Blower Assembly)
9-2/5 x 6-1/2 x 2-3/4 in. (240 x 165 x 70 mm)
Weight
2.4KG
Air Filter
1*P2
Air Flow
Level 1: >=165L/min
Level 2: 200L/min
Level 3: 230L/min
Noise Level
Max 73dB
Operating Temperature
23ºC to 131ºC (-5ºC~55ºC)
Storage temperature
14ºC to 131ºC (-10ºC~55ºC)
Battery Type
Rechargeable Li-ION 4400mAh
Expected Battery Operation Time
Level 1>8h
Level 2>6h
Level 3>4h
Battery Charging Time
3.5 Hours
Battery Life
500 Charges
Run Time Dependent On Air Flow Rate and Filter Load.
LCD Display
Air flow level and data
Battery capacity
Filter status
Belt Size
35-2/5 x 51-2/5 in. (900mm to 1300mm)
10: SPECIFICATION