11.4 Cleaning Inside the Enclosure
Dust is produced from ticket stock passing through the transport mechanism. Use the following procedure to clean inside the
Unit enclosure (left paper stock side):
11.4.1 Toggle the power switch to
O
(OFF) and unplug the power cord from the rear of the Unit.
CAUTION
Take caution when opening the left side door. Refer to “Installation” section
for details on how the left door opens and the space required.
11.4.2 Unlock the door on the left side of the Unit and swing it open.
11.4.3 Back the ticket stock all the way out of the transport mechanism by turning the knurled knobs shown in the figure
above.
11.4.4 Remove ticket stock as necessary and vacuum dust from inside of Unit.
11.4.5 Using compressed air, blow the dust from ticket stock path grooves in transport mechanism.
11.4.6 Using compressed air, blow the dust off the sensors in the ticket stock path. Refer to the diagram on the left side
door (internal panel) or the sensor location figures in the “Clearing Stock Jams” section.
11.4.7 After all cleaning is complete, plug the power cord back into the rear of the Unit, toggle the power switch to
I
(ON),
and reload the ticket stock. Refer to the “Basic Unit Operation and Setup” section.