To add a new smoke alarm to the interlinked group carry out the
Wireless interlinking of
smoke alarms
for the new and all the other smoke alarms.
Verification of interlink between smoke alarms
Install all interlinked smoke alarms to bases. Press and hold on the Test button on one of
them (Test mode). After the period of 10 to 30 sec. all interlinked smoke alarms will go to the
Remote Alarm mode. Upon releasing the Test button, the other alarms will stay in the Remote
Alarm for 5..10 sec.
To use the alarm do the following:
-
interlink the smoke alarms
-
fix the base where necessary
-
install the detector to the base and twist it clock-wise until it clicks. You will hear the
tune.
To turn off the smoke alarm:
-
remove the detector from the base, rotating it anti-clockwise as far as it goes.
Modes:
Alarm:
If smoke has been detected the smoke alarm gives a loud and continuous alarm signal and
the red LED light will flash continuously until the smoke disappears. As soon as the smoke alarm
goes to the Alarm mode it will start transmitting alarm signals to all interlinked smoke alarms.
Within 20 sec. all interlinked smoke alarms will go to the Remote Alarm condition.
Remote Alarm:
If one of interlinked alarms has gone to the Alarm status, then within 20 sec. all other
interlinked alarms will go to the Remote Alarm status. Only sound alarm indication is present in
the mode (no visual indication). Sound signal is retained within 5..10 more sec. after switching
off the Alarm status on the master alarm.
Hush mode
(Reduced Sensitivity)
:
Press the TEST/HUSH button for no longer than 2 sec.
The red LED light will now flash approx. every 10 seconds during approx. 10 min. This means
the smoke alarm is functioning properly and the smoke alarm will stay for approx. 10 minutes in
the HUSH mode.
NB.
HUSH mode can be reset with Remote alarm
Test mode:
Push and hold on the test button for at least 2 seconds.
If the sensor works properly then the smoke alarm will issue the alarm sound signal and then
the red LED will flash as long as the Test button is held on. In 10 sec. of holding the button the
alarm signal will be transmitted to all the interlinked smoke alarms and after that within 20 sec.
all the interlinked and installed to the base smoke alarms will go to the Remote Alarm status.