uniLIGHT BLACK.1 Manual Download Page 2

Creative Solutions, 05-2014 

 

 

A.

 

Reciever 

Use included cable for connection 

B.

 

Status Output  

C.

 

SET/STORE Button 

D.

 

Status System/Programming 

E.

 

Power supply of output channels 

F.

 

Light output, 3A 

 

 

Technical Data 

 

 

 

 

MODUL-BLACK.1 

  

MODUL-2-150-2

 

Receiver side: 

 

  

 

 

 

4.8-9.6V 

 

 

4.8-9.6V 

Weight (exkl. Cables): 

 

 

 

 

1.5g 

 

 

 

8g 

Dimensions: 

 

 

 

 

 

45x14x6mm 

 

 

45x35x8mm 

Current per channel:  

 

 

 

 

3A, up to 16V    

 

1.5A, up to 30V 

Maximum current (5s):    

 

 

 

5A, up to 16V    

 

3A, up to 30V 

galvanic separated: 

 

 

 

 

 

 

 

YES 

Operation without RC possible: 

 

 

 

YES 

 

 

 

YES 

Light effect with various speed: 

 

  

 

11 

 

 

 

11 

Short circuit protection 

 

 

 

 

YES 

 

 

 

Deep discharge protection 

 

 

 

YES 

 

 

 

Specials 

Start the receiver power while pressing the SET button and keep it for about 10 seconds. Once the blinking 
light signal transitions into a running light, the reset has been performed and the default setting is restored. 

Safety functions 

1.

 

In case of short circuit or massive overload the output will be switched off immediately. The blue LED will 
flash. After 10 seconds pause the controller will try to resume the operation. Maybe you have to restart the 
controller. 

2.

 

In  case  of  low  battery  the  output  is  also  turned  off.  The  blue  LED  is  blinking  slower.  The  controller  will 
continue the operation for two seconds each 10 seconds to show the low battery operation. Please charge! 

 
 
For more information and further manuals visit www.unilight.at 