3/5
FR-DM-17 REV.03 EFF 15/09/17
For 1-10V dimming and DALI system.
C
B
A
Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.
Ø
7.1 -13 mm.
2
ÊíÒËÃѺÃкº´ÔÁ1-10VáÅÐÃкºDALI
A = 38-40 mm.
B = 8-10 mm.
C = 30-32 mm.
Green/Yellow (ÊÕà¢ÕÂÇ/ÊÕàËÅ×ͧ) :
Brown (ÊÕ¹éíÒµÒÅ) : L
Blue (ÊÕ¹éíÒà§Ô¹) : N
White (ÊÕ¢ÒÇ) : +
Black (ÊÕ´íÒ)
: -
IP68 water tight connecting device 5 Pole.Cable Diameter 7.1-13mm.
Available Separately/ ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 5 ÊÒÂ
¨íÒ˹ÒÂᡵҧËÒ¡
Ordering Code : 0413-0-9-000-00
1.
2.
3.
4.
5.
Remark :
ËÁÒÂà˵Ø
Installation should be carried out by a qualified
electrician in accordance with appropriate national
wiring regulation.
¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ
¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò ã¹¡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁ
ÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò
Disconnect the power before changing the lamp.
»´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿
For Class1 luminaire, the installation must be completed
with earthing.
ÊíÒËÃѺâ¤Áä¿·ÕèÁÕ¡Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇÃдѺ1 ¡ÒõԴµÑ駵ͧµÍÊÒÂ
´Ô¹µÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ´ÇÂ
Do not exceed the maximum wattage.
ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ·
Don't touch LED while maintaining or cleaning.
ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´
1.
2.
Warning :
¢Í¤ÇÃÃÐÇѧ
The manufacturer will not be liable or held responsible
for any incorrect installation, misuse or improper use
and unauthorised modification to the fittings. Failure
to comply with mentioned warning may cause serious
damage or serious injury to persons, animals or
objects. If any modification is required please consult
your dealer for the details.
·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒÃ
µÔ´µÑé§äÁ¶Ù¡ÇÔ¸Õ, 㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ
«Öè§ ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ
ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº
¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ
Where damage has occured to the fittings, please
make the replacement with standard parts before use.
㹡óշÕèÁÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕ蹪Ôé¹
ÊǹãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑÂ
Place the gravel 20-30 cm.depth underneath the casing for water
drainage (Pic-1).Then do the testing by filling water into the casing
and let it drain.The water should be drained out by 30 minutes.
If not,the additional drainage pipe or other system must be applied
(Pic-2)
¤ÇÃÇÒ§¡Í¹¡ÃǴ㵡Åͧ½§¾×é¹·ÕèÃÐÂÐÅÖ¡»ÃÐÁÒ³ 20-30 «Á. à¾×èͪÇÂÃкÒÂ
¹éíÒ·Õè·ÇÁ¢Ñ§µÑÇâ¤Áä¿ ÊÒÁÒö·´Êͺ¡ÒÃÃкÒ¹éíÒâ´Âà·¹éíÒãÊ¡ÅͧãËàµçÁ
¹éíҨеͧÃкÒÂÍÍ¡ËÁ´ÀÒÂã¹àÇÅÒ 30¹Ò·Õ ËÒ¡äÁ໹µÒÁ¹Ñ鹤ÇÃÁÕ¡ÒõÍ
·ÍÃкÒ¹éíÒà¾ÔèÁàµÔÁ
General installation guide ( highly recommended)
¢Íá¹Ð¹íÒ㹡ÒõԴµÑé§
Pic-1
ÃÙ»-1
Pic-2
ÃÙ»-2
20-30 cm.
Water drainage pipe
·Í¹éíÒ·Ôé§
Cable pipe
·ÍÊÒÂä¿
Last Revised On : 14/05/2021 REV.02