Safety references

 

 

Safety References

 

 

The  respective  accident 

prevention 

regulations 

established 

by 

the 

professional  associations  for 

electrical 

systems 

and 

equipment  must  be  strictly 

met at all times.

 

 

In  order  to  avoid  electrical 

shock,  the  valid  safety  and 

VDE  regulations  regarding 

excessive  contact  voltages 

must 

receive 

utmost 

attention,  when  working  with 

voltages  exceeding  120V 

(60V) DC or 50V (25V) rms AC. 

The  values  in  brackets  are 

valid for limited ranges (as for 

example 

medicine 

and 

agriculture).

 

 

Measurements  in  dangerous 

proximity of electrical systems 

are  only  to  be  carried  out  in 

compliance 

with 

the 

instructions  of  a  responsible 

electronics  technician,  and 

never  alone.

 

 

If  the  operator’s  safety  is  no 

longer 

ensured, 

the 

instrument is to be put out of 

service 

and 

protected 

against  use.  The  safety  is  no 

longer 

insured 

if 

the 

instrument:

 

 

shows obvious damage

 

 

does not carry out the desired 
measurements

 

 

has been stored for too long 
under unfavorable conditions

 

 

has been subjected to 
mechanical stress during 
transport.

 

 
 
 
 

Summary of Contents for EVSE X7

Page 1: ...EVSE X7 Adapter EV Charger Tester ...

Page 2: ... ...

Page 3: ...niks it The registration of your products will allow you to stay informed about news take advantage of advantageous discounts dedicated to you for the purchase of accessories and products for your daily work Registration is free ...

Page 4: ...l 6 Safety References 7 Testing 8 Purpose of the EVSE X7 accessory 8 Test procedure 9 Proximity Pilot PP State Cable Simulation 10 Control Pilot CP State Vehicle Simulation 10 CP Signal output terminals 11 CP Error E simulation 12 Measuring terminals 12 Cleaning 12 ASSISTANCE 14 WARRANTY CONDITIONS 14 ASSISTANCE 15 ...

Page 5: ...5 Operation Elements And Connectors 1 Type 2 plug 2 Slider switch for CP Mode selection 3 Test leads with 4mm safety plugs for L1 L2 L3 N PE CP and PP Adapter is equipped with 0 5 m test leads ...

Page 6: ... EN 61326 is fulfilled It also complies with the Low Voltage Directive 2014 35 EU Standards EN 61010 1 and EN 61010 031 Instrument fulfils the standard 2012 19 EU WEEE This marking indicates that this product should not be dis posed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to pr...

Page 7: ...e values in brackets are valid for limited ranges as for example medicine and agriculture Measurements in dangerous proximity of electrical systems are only to be carried out in compliance with the instructions of a responsible electronics technician and never alone If the operator s safety is no longer ensured the instrument is to be put out of service and protected against use The safety is no l...

Page 8: ...y be used under those conditions and for those purposes for which it was conceived For this reason in particular the safety references the technical data including environmental conditions and the usage in dry environments must be followed When modifying or changing the instrument the operational safety is no longer ensured Testing Purpose of the EVSE X7 accessory The UNIKS EVSE X7is an accessory ...

Page 9: ...Test procedure connect the needed 4 mm test plugs of the UNIKS EVSE X7to your MFT select CP Mode A with the slider switch connect UNIKS EVSE X7to the Type 2 connector of the charging point select CP Mode B with the slider switch the charging point should show ready to charge select CP Mode C with the slider switch the charging point should start charging perform all measurements in active stage of...

Page 10: ...SE X7is configured internally to setup 32 A current capability Control Pilot CP State Vehicle Simulation With the CP Mode slider switch various vehicle states can be simulated Vehicle states are simulated with different resistances connected between CP and PE conductors Correlation between resistance and vehicle states is shown in Table below ...

Page 11: ...Ω 0V Testing CP Signal output terminals CP output terminals are short connected to the CP and PE conductors of the tested charging station via the test cable Use an oscilloscope to check the waveform and amplitude of the CP signal Control Pilot function uses Pulse Width Modulation PWM to code communication between a vehicle and charging station The duty cycle of the PWM signal defines the possible...

Page 12: ... 1 In the case of CP Error E is pushed result should be aborting of the charging process and new charging process is prevented Measuring terminals All terminals inside the Type 2 connector L1 L2 L3 N PE CP and PP are available on 4 mm safety connectors with double insulated wires according to IEC 61010 031 It is allowed to use these for measuring purposes only It is not allowed to draw cur rent ov...

Page 13: ...0 Hz Measurement Category CAT II 300V Main socket rating max 10A PP simulation configurazione interna a 32 A CP simulation Stati A B C Error simulation Errore CP E Test connector type IEC62196 2 Tipo 2 maschio Type 2 male Test cable length 0 5 m Working temperature 0 40ºC Storage temperature 10 50ºC Humidity 0 80 RH Compliance to IEC 61010 1 IEC 61010 031 ...

Page 14: ...erted For shipping only use the original packaging Any damage caused by the use of non original packing shall be charged to the customer The manufacturer accepts no responsibility for damage caused to people or objects The warranty does not apply in the following cases Repair and or replacement of accessories and battery not covered by warranty Repairs made necessary because of a misuse of the ins...

Page 15: ...tery and wear of the cables and replace them if necessary If the instrument continues to manifest malfunctions check if the procedure of use of the same is in accordance with what is indicated in this manual If the instrument is to be returned to the after sales service or to a dealer transportation is borne by the customer The shipment must however be agreed Attached to dispatch an explanatory no...

Page 16: ...16 Uniks Srl https www uniks it info uniks it Via Vittori 57 48018 Faenza RA Italy 0546 623002 0546 623691 ...

Reviews: