RACK POWER

U S E R   I N S T R U C T I O N S

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

INPUT VOLTAGE

LOAD CURRENT

SEQUENCE

DELAY

2.0

3.0

4.0

1.0

SECONDS

MAXIMUM LOAD 

AC~220V 50Hz

MAX 30A

LINE

AC~220V 50Hz

MAX 30A

UNiK A

RACK POWER

Po w e r S e q u e n c e r

220

00.2

POWER

BREAKER

OFF

ON

ON

1. Power Switch: Press this POWER push button to initiate the sequence to turn on the outlets in order from CH1 to CH8 
    when sequencing on, and turn the outlets off in the reverse order from CH8 to CH1 when sequencing off.

2. Outlet Circuit: These 8 LED's indicate the status of circuit from CH1 ~ CH8.

3. Output Load Current: This large size of LED display indicates output load current.

n d

4. High Current Outlet: User can easily to use the plug (figure-1) for safety connection to the 2  RACK POWER
    or other device.

5. High Current Inlet: User can use the connector (figure-2) for safety connection to the mains input power. 

6. Circuit Breaker: This is a 30A fast acting main circuit breaker for the device's power ON/OFF control and it also 
    serve as current overload protection.

7. Input Voltage: This large size of LED display indicates input voltage.

8. Sequence Delay: The 8 AC outlets on the rear panel are able to sequentially power on or power down. The sequence 
    delay interval is user-adjustable from 0.4sec to 5sec via the trimpot on the front panel.

9. AC Mains operating voltage 120Vac/60Hz or 220Vac/50Hz single Phase, Mains operating voltage of the device need 
    to be specified upon order.

 (Figure-1) 

 (Figure-2) 

1

2

3

4

5

6

7

8

9

Front Panel

Summary of Contents for RACK POWER

Page 1: ...he proper and safe operation i i i i RACK POWER www unika com tw CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 INPUT VOLTAGE LOAD CURRENT SEQUENCE DELAY 2 0 3 0 4 0 1 0 SECONDS MAXIMUM LOAD AC 220V 50Hz MAX 30A LIN...

Page 2: ...RACK POWER U S E R I N S T R U C T I O N S Important Precautions and Features 2 Front Panel 3 Rear Panel 4 Operating Instructions and Specifications 5 Connector And Plug Assembly 6 page 1...

Page 3: ...c motors power supplies and power amplifiers of all kinds sequenced powering can avoid excessive inrush currents that cause circuit breakers to trip even though the steady state currents are not exces...

Page 4: ...rent nd 4 High Current Outlet User can easily to use the plug figure 1 for safety connection to the 2 RACK POWER or other device 5 High Current Inlet User can use the connector figure 2 for safety con...

Page 5: ...MAXIMUM LOAD 30A RACK POWER L N L N L N L N CH 5 CH 6 CH 7 CH 8 CH 1 CH 2 CH 3 CH 4 11 10 10 CH1 CH4 Power Outlets 3 prongs universal AC outlet rated 13A 250Vac 11 CH5 CH8 Power Outlets Powercon AC o...

Page 6: ...ication 7 Blue 32A 3 Contact High Current Straight Inlet and Outlet front Panel mount sockets for the ease and safety connection of the mains input power 8 Use the Blue 32A 3 Contact High Current In l...

Page 7: ...Live Hot L Ground G Live Hot L Ground G Neutral N Each set of RACK POWER includes 1 piece each of the input connector and output plug Please see the following drawings to assemble these connector and...

Page 8: ......