background image

2

UNiKA 

PRO IS2

  

 

 

User Manual

FEATURES

• 

One input & three output audio splitter

• 

CH-1/CH-2 are equipped with separate UNiKA-PRO

TM

 EI9AE3R3 1.25:1 isolation 

transformer

• 

Use XLR jack for input

• 

Set the PHASE REVERSE button for CH-2 input

• 

The output is equipped with independent GND/LIFT switches

PARAMETER TEST CONDITIONS

In the development and manufacturing process, Audio Precision's 2700 series and 500 

series are used to test and verify electrical characteristics.

WHEN TO USE PRO IS2

PRO IS2's CH-1/CH-2 are each equipped with independent EI9AE3R3 professional audio 

isolation transformer, which is a transformer that works in the audio range, also known as 

a low-frequency transformer. The frequency range is generally from 20 to 20000 Hz. It is 

mainly used for audio transmission between systems or devices. It can completely isolate 

the potential difference between two systems, avoid hum interference caused by ground 

loop problems, and prevent excessive potential difference from damaging the input level 

of the device. The safe transmission of signals is an essential product for long-distance 

transmission of analog audio systems.

However, since it does not have an input amplifier circuit and attenuator, it can only transmit 

balanced signals through an isolation transformer or convert unbalanced signals into 

balanced signals for transmission, and does not have the function of increasing the level. If 

the input signal is of a high-impedance type, such as musical instruments or some players, 

it is recommended to use other DIs with input attenuators in the PRO series to transmit 

signals. These DIs also have built-in EI9AE3R3 professional audio isolation transformer.

The CH-2 is attached with an invert button. If your wire's hot pin is pin-3, you can press this 

button to switch the hot pin to pin-2.

Each output has an independent GND/LIFT button to ground or float pin-1 of the output to 

eliminate noise or leakage in the event of ground noise or inadvertent ground loops.

Summary of Contents for PRO IS2

Page 1: ...OUND LOOP NOISE CONNECTORS WIRING GUIDE SYSTEM CONNECTION GUIDE STAGE SYSTEM CONNECTION GUIDE FIXED INSTALLATION SPECIFICATIONS 6F No 168 Xin Hu 2nd Rd Nei Hu District Taipei City 11494 Taiwan R O C 8...

Page 2: ...NTERFACE Before using please read this manual carefully and pay attention to every detail that you must pay attention to If you use a mixer to connect to this interface please turn off the mixer power...

Page 3: ...nterference caused by ground loop problems and prevent excessive potential difference from damaging the input level of the device The safe transmission of signals is an essential product for long dist...

Page 4: ...should depend on the system Used in the situation in order to isolate the ground loop noise or leakage CH 1 signal output XLR terminal pass through the isolation transformer CH1 input One combo jack...

Page 5: ...e can be eliminated through the GND LIFT button The GND LIFT button determines whether pin 1 of the output XLR is grounded grounded when it bounces and disconnected from ground when pressed ELIMINATIN...

Page 6: ...ge and F O H be powered by different power supply source SYSTEM CONNECTION GUIDE STAGE FOH CONSOLE SELF POWERED STAGE MONITOR OR FOH SPEAKER POWERED BY DIFFERENT POWER SOSURCE MONITOR OR PRODUCTION CO...

Page 7: ...6 UNiKA PRO IS2 User Manual When the main and extension system be used by dif ferent power supply source SYSTEM CONNECTION GUIDE FIXED INSTALLATION REAL TIME RECORDING MAIN VENUE...

Page 8: ...through ISO Transformer Output GND LIFT switch Independent push button for each channel Frequency response 20Hz 20KHz 0 3 0 1dB S N ratio 20Hz 20KHz un weight 120dB T H D 1KHz 0dBV output 0 02 Transf...

Reviews: