Unika PD-1 User Manual Download Page 3

11. AC Power Cord - 

Plug this cable into a standard 110V or 220V wall outlet. Be sure 

that the supplied voltage in your area matches the unit's required voltage. Never 
plug your power conditioner into a wall outlet that does not match its required

 

voltage which helps to avoid serious damage may occurred on the unit.

12. XLR lamp connector - 

This is used to connect the detachable gooseneck lamp.

13. Power Output (CH1~CH8) - 

For CH6~CH8, 3 outlets with wall wart spacing.

REAR PANEL

FEATURES

All PD series models (PD-1/2/3)

8 rear panel outlet and 1 unswitched font panel convenience outlet.

3 outlets with wall wart spacing

Total power capacity of 1800watts

EMI and RFI filtering

Surge and spike protection

Rear XLR lamp connector for gooseneck lamp detachable

Front panel resettable circuit breaker and power illuminated switch

For PD-1

3 additional front panel outlets (total 11 switched outlets, 1 unswitched outlet)

For PD-2

LCD digital voltmeter/ammeters/system clock

Hour and Minute buttons for time set up

For PD-3

LCD digital voltmeter/ammeters/system clock

Hour and Minute buttons for time set up

2 front panel pull-out LED light pipes with front LED on/off switch

Rear light on/off switch for gooseneck lamp

Page 2

MAXIMUM LOAD

The eight circuit breaker protected outlets are rated at 15 amps total, which is equivalent 
to 1800 watts at 120 volts. If the total load exceeds 15 amps, the circuit breaker will trip, 
cutting off power to your rack. If this happens, reduce the load by unplugging one or 
more units from the unit, then push the circuit breaker button in to reset it.

OPERATION

All the PD Series with the same rear panel as below:

PD-1 / 2 / 3

AC IN

 LIGHT

 ~12V 420mA

~120V 50/60Hz 

15A

CH8/10A

CH7/10A

CH6/10A

CH5/10A

CH4/10A

CH3/10A

CH2/10A

CH1/10A

TOTAL MAX 15A

13

11

12

Reviews: