Unika 4711064410198 User Manual Download Page 6

UNiKA

 

PRO 248

 

   

User Manual

5

The most widely used DI box is to connect electronic 

musical instruments, sound source of A/V equipment 

and computers, convert their output signals into 

balanced signals and then extend the transmission 

distance.

The most ideal state is to set the attenuator to 0dB 

position (button up) for musical instrument. For some other type of signals, you can press 

the button to make the signal is attenuated by 20dB to avoid clipping caused by signal 

overload. 

When the button is pressed, the PAD indicator on the right will light up.

This attenuator acts on the input terminals of CH-1 and CH-2 at the same time.

INPUT PAD ATTENUATION

The built-in channel independent balanced isolation 

transformer has solved the potential difference leakage 

problem. When the system causes a ground loop due 

to poor wiring, the noise can be eliminated through the 

GND/LIFT button.

The GND/LIFT button determines whether pin 1 of the 

output XLR is grounded, grounded when it bounces, 

and disconnected from ground when pressed.

ELIMINATING GROUND LOOP NOISE

POWER SUPPLY

PRO 248 is an active DI box and re48V 

phantom power. It can work normally when it is 

powered, but no additional power supply is required. 

Just use balanced wires to connect the device to the 

mixer’s input channel, and turn on the +48V power 

switch of the mixer,  similar to connect a condenser 

microphone to the mixer.

When the +48V power supply is suppling properly, the 

+48V ACTIVE indicator light on the upper cover will 

light up.

Before connecting the device, do not turn on 

the +48V switch of the mixer.

Summary of Contents for 4711064410198

Page 1: ...PULSE TRANSFORMER SCHEMATIC INPUT PAD ATTENUATION POWER SUPPLY ELIMINATING GROUND LOOP NOISE CONNECTION GUIDE SPECIFICATIONS 6F No 168 Xin Hu 2nd Rd Nei Hu District Taipei City 11494 Taiwan R O C 886...

Page 2: ...PRO 248 uses 48V phantom power instead of the traditional 9V dry cell battery so users can use it on the mixer or external phantom power supply Power is supplied to PRO 248 the power supply circuit an...

Page 3: ...10E isolation transformer Use British OEP PT 4 1 1 audio pulse transformer in phantom power circuit 48V status indicator on the upper cover The input socket uses a pair of TRS jacks Use a pair of TRS...

Page 4: ...to turn on 48V phantom power supply for PRO 248 proper working after connecting to the mixer 48V phantom power indicator When CH 1 or CH 2 receive 48V phantom power the indicator will be shinning the...

Page 5: ...NSFORMER SCHEMATIC 1 5 10 6 Screen Secondary Cooper foil Core Secondary Primary Primary PULSE TRANSFORMER SCHEMATIC UNiKA PROTM EI30A10E OEP PT 4 3 layers of thermo setting adhesive polyester tape bet...

Page 6: ...alanced isolation transformer has solved the potential difference leakage problem When the system causes a ground loop due to poor wiring the noise can be eliminated through the GND LIFT button The GN...

Page 7: ...n 2 Hot pin 3 Cold pin The unbalanced connection pin 2 is hot pin 3 is shield paralleled with pin 1 Output from musical instrument to INPUT Output via THRU OUT to musical instrument amplifiers 1 2 3 1...

Page 8: ...ut GND LIFT switch Shared push button Input impedance 260K 0dB 50K 20dB Output impedance 50 Max input level before clipping 10dB Max Output level 10dB Frequency response 20Hz 20KHz 0 05 0 5dB S N rati...

Page 9: ...entioned above The results of testing in this report apply only to the product system which was tested Other similar equipment will not necessarily produce the same results due to production tolerance...

Reviews: