![Unigas PN30 Operating & Maintenance Instructions Download Page 14](http://html.mh-extra.com/html/unigas/pn30/pn30_operating-and-maintenance-instructions_842314014.webp)
PART I: INSTALLATION MANUAL
14
VISCOSITY VS TEMPERATURE DIAGRAM
Fig. 13
VISCOSITY vs. TEMPERATURE DIAGRAM
BEST VISCOSITY RANGE FOR A
PROPER ATOMIZATION
1,2
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2
50
60
70
80
90
100
110
120
130
140
150
160
170
180
TEMPERATURE (°C)
VI
SC
O
S
IT
Y
(°
E
)
3°E AT 50°C
5°E AT 50°C
7°E AT 50°C
12°E AT 50°C
15°E AT 50°C
20°E AT 50°C
50°E AT 50°C