PART I: INSTALLATION MANUAL
24
Example (Fluidics):
as for over 100kg/h nozzles, the 80% of the nozzle flow rate can be obtained with a return pressure at about 18bar
(see Fig. 32).
FLUIDICS NOZZLE: REFERENCE DIAGRAM (INDICATIVE ONLY)
Tab. 1
NOZZLE SUPPLY PRESSURE = 25 bar
- - - - - -- - -
Atomisation angle according to the return pressure
_________
% Flow rate
ATTENTION! To achieve the maximum flow rate close completely the return line.
FLOW RATE kg/h
DIMENSIONS
Min
Max
40
13
40
50
16
50
60
20
60
70
23
70
80
26
80
90
30
90
100
33
100
115
38
115
130
43
130
145
48
145
160
53
160
180
59
180
200
66
200
225
74
225
250
82
250
275
91
275
300
99
300
330
109
330
360
119
360
400
132
400
450
148
450
500
165
500
550
181
550
600
198
600
650
214
650
700
231
700
750
250
750
800
267
800
Pressure on return (psi)
Up to 100kg/h
Over 100kg/h
Flow rate
Atomisation angle
Pressure on return (bar)
Summary of Contents for HTLX 1025.1
Page 47: ...PART III MAINTENANCE 47...
Page 49: ...Siemens LMV5x Service Manual M12920CC rev 2 1 08 2017...
Page 56: ...8...
Page 60: ...12 2 2 LMV5x program structure...
Page 87: ...39...
Page 94: ......
Page 95: ......
Page 96: ...Note Specifications and data subject to change Errors and omissions excepted...
Page 98: ...Annex1 Example for motor cable...
Page 99: ......
Page 100: ...Annex 2 Example for sensor cable...
Page 101: ......
Page 102: ......
Page 106: ......