Table 3-3
Parameter – Manual Alarm, example
Parameters
Sample Value
Alarm Key SP
On
Alarm Key LP
On
Alarm Key locked
Off
Alarm Signal SP
On
Alarm Signal LP
Off
Alarm Destination SP
6647201
Alarm Destination LP
6647208
Configuration and activation
A31003-M2000-M103-2-76A9, 07/2014
3-7
Alarm and Emergency Call Configuration, Administrator Documentation
SHB_PNG-Konfig.fm
Configuration menu
Wide-ranging solutions are feasible using different configuration options. Example of a silent
alarm when the alarm key is pressed and held down (longpress):
Non Movement Alarm
>
The Non Movement Alarm can be activated optionally. It is triggered if the sensors identify lack
of movement over a defined configurable period of time.
For more information on alarm destinations please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1.
Select the
Additional Features
icon in the main menu.
2.
Select
Configuration
.
3.
Enter the five-position service PIN and confirm with
OK
.
4.
Select one of the three operating modes.
5.
Select
Alarms
.
6.
Select
Non Movement Alarm
.
7.
Change the values of the following parameters:
The response time and the prealarm time cannot be added, rather the prealarm time
has to be deducted from the response time. For example, a response time of 90 s
and prealarm time of 15 s means that the prealarm will be triggered after 75 s and
the alarm after 90 s.