Activation of the pull cord alarm is optional. The pull cord alarm is triggered when the pull cord
contact cannot be identified for a defined and configurable period of time (inother words, when
the cord has been detached).
Table 7-14
Parameter setting for pull cord alarm
7.2.3.6
Technical Warning
Activation of signalling for a local technical fault is optional. An alarm is not signalled to the
PNEZ. The handset only alerts the user who can then respond to the warning.
The technical warning can be reset using the same method described for the prealarm. The
monitoring timers are restarted.
You can configure the following parameters:
●
Activation: technical fault monitoring can be activated or deactivated.
●
Locate req. time: checks whether the handset is receiving regular DPS requests. The
check is deactivated when "Locate req. time" = 0.
●
Acoustic
●
Out of range time: checks whether the handset has contact with the base station. The
check is deactivated when "Out of range time" = 0.
The handset also checks whether the battery is sufficiently charged. A technical fault is report-
ed if the battery is too low.
Parameter
Setting range
Factory setting
BGR 139
Activation
On/Off
On
At least one autom.
alarm
Response time
10 s ... 900 s
30 s
<= 30 s
Prealarm time
0 s ... 30 s
15 s
0 s ... 15 s
Alarm Signal
On/Off
On
On
Alarm destination
32-digit number
Blank (see Section
7.2.1.1, “Alarm Num-
ber Basis”)
Align with PNEZ
Parameter
Setting range
Factory setting
BGR 139
Activation
On/Off
On
On
Locate req. time
0 min ... 30 min
0 min (check off)
<= 10 min