background image

10 

OM-FX SERIES

Maintenance

Unified Brands strongly suggests a preventive maintenance program which would include 

the following 

Monthly

 procedures:

1.  Clean fan blades on the condensing unit and evaporator assembly.

2.  Clean all gaskets on a weekly if not daily basis with a solution of warm water and a 

mild detergent to extend gasket life.

3.  Lubricate door hinges with lithium grease. Modify for FX drawer slides and verify with 

engineering

RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING:

JOB

CLEANING AGENT

COMMENTS

Routine cleaning

Soap, ammonia, 
detergent Medallion

Apply with a sponge or cloth

Fingerprints and smears

Arcal 20, Lac-O-Nu, Ecoshine

Provides a barrier film

Stubborn stains and 
discoloration

Cameo, Talc, Zud, 
First Impression

Rub in the direction of the 
polish lines

Greasy and fatty acids, blood, 
burnt-on foods

Easy-Off, Degrease It, 
Oven Aid

Excellent removal on all 
finishes

Grease and Oil

Any good commercial 
detergent

Apply with a sponge or cloth

Restoration/Preservation

Benefit, Super Sheen

Good idea monthly

Reference:  Nickel Development Institute, Diversey Lever, Savin, Ecolab, NAFEM

Proper maintenance of equipment is the ultimate necessity in preventing costly repairs.  By 

evaluating each unit on a regular schedule, you can often catch and repair minor problems 

before they completely disable the unit and become burdensome on your entire operation.

For more information on preventive maintenance, consult your local service 

company or CFESA member.  

Most repair companies offer this service at very reasonable 

rates to allow you the time you need to run your business along with the peace of mind 

that all your equipment will last throughout its expected life.  These services often offer 

guarantees as well as the flexibility in scheduling or maintenance for your convenience.

For a complete listing of current Unified Brands ASA please visit www.unifiedbrands.net.

Unified Brands believes strongly in the products it manufactures and backs those products 

with one of the best warranties in the industry.  We believe with the proper maintenance and 

use, you will realize a profitable return on your investment and years of satisfied service.

DO NOT USE SHARP UTENSILS AND/OR 
OBJECTS.

CAUTION
DO NOT USE ABRASIVE CLEANING 
SOLVENTS, AND NEVER USE HYDROCHLORIC 
ACID (MURIATIC ACID) ON STAINLESS STEEL.

DO NOT USE STEEL PADS, WIRE BRUSHES, 
SCRAPERS, OR CHLORIDE CLEANERS TO 
CLEAN YOUR STAINLESS STEEL.  

DO NOT PRESSURE WASH EQUIPMENT AS 
DAMAGE TO ELECTRICAL COMPONENTS 
MAY RESULT.

Summary of Contents for Randell FX Series

Page 1: ...ammable vapors and liquids in the vicinity of this or any other appliance WARNING R290 flammable refrigerant in use Improper installation adjustment alteration service or maintenance can cause propert...

Page 2: ...g page 4 5 Equipment Description page 6 Installation page 7 Operation page 8 9 Maintenance page 10 Troubleshooting page 11 Service page 12 Parts List page 13 16 Electrical Schematic page 17 Service Lo...

Page 3: ...roper maintenance will provide years of trouble free service to its owner In addition all Unified Brands food service equipment is backed by some of the best warranties in the food service industry an...

Page 4: ...4 OM FX SERIES The following warning labels will be found on your equipment INTERIOR EVAPORATOR COVER NEAR MACHINE COMPARTMENT AND NAMEPLATE Labeling...

Page 5: ...OM FX SERIES 5 EXTERIOR OF UNIT NEAR EXPOSED REFRIGERANT TUBING Labeling...

Page 6: ...0 1 3 4 5 15P 2 635 FX 2WSA 290 43 3 28 36 2 2 5 1 58 3 4 1 4 2 115 60 1 3 4 5 15P 2 635 FX 2WSRE 290 35 34 5 36 2 2 6 2 1 76 3 3 1 4 2 115 60 1 3 4 5 15P 2 635 FX 2WSREA 290 35 34 5 33 2 5 1 58 3 4 1...

Page 7: ...adjustments are required the control is located on the front panel Confirm that the unit is holding the desired temperature 5 Refer to the front of this manual for serial number location Please recor...

Page 8: ...ol adjustment until desired temperature is reached DANFOSS CONTROLLER OPERATION LED FUNCTION Compressor energized Evaporator fan de energized Defrost in progress Fans delay after defrost completion Ev...

Page 9: ...ng Alarms Visual Display Only 1 After 2 minutes the display will flash the alarm message dor 2 Press any button to acknowledge alarm DRAWER DOOR ALARM Door Alarm Activation If audible alarm is wanted...

Page 10: ...t is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can often catch and repair minor problems before they completely disable the unit and become...

Page 11: ...ll for service at 888 994 7636 Unit too cold Incorrect set point Adjust control set point Unit too warm Door drawer ajar Ensure door drawer is fully closed Gasket torn or out of place Inspect the gask...

Page 12: ...n free dry nitrogen with a trace gas not exceeding 200PSI When accessing an R290 system piercing valves are not to remain on the equipment in a permanent manner After charge is recovered Schrader valv...

Page 13: ...PHILLIPS TRUSS SS 3 FA NUT0312 RIVNUT 6 32 THD 4 RF CMP1604 COMPRESSOR 3 8 HP LO 404 115V DANFOSS 4a RF CMP1604SC COMPRESSOR START COMPONENTS 5 RF FLT9902 DRYER 1 4x 042 FILTER EKP 032 SC DBL INL CAP...

Page 14: ...SIDE EXTERIOR S S LEFT 6 RP BCK1701 BACK EXTERIOR 7 HD TRK1101_BASE TRACK DWR SLIDE L H 2 1 8 X 28 BAYONET MNT 8 HD TRK1102_BASE TRACK DWR SLIDE R H 2 1 8 X 26 650MM BAYONET MNT 9 RP CPN0601 PAN COND...

Page 15: ...EA 1B RP PAN0801 INSULATED DRAWER TUB FOR FX 1UC 2 RP GSK0604 GASKET MAGNETIC SLIDE SEAL PF 765 X 614mm 3 RP DWR1603 DRAWER CARRAIGE ASSY W FRONT FX 1 FX 1RE 3A RP DWR1504 DRAWER CARRIAGE ASSY W FRONT...

Page 16: ...MIT 6 RF TRM0501 THERMODISC 2 WIRE OPEN 70 CLOSE 50 SEO 70 T17 7 RP GSK0604 GASKET MAGNETIC SLIDE SEAL PF 765 X 614mm 8 RF DIF0601 DIFFUSER LID FOR FX 1 FX 1A FX 1RE FX 1REA 8A RF DIF0801 DIFFUSER LID...

Page 17: ...OM FX SERIES 17 Electrical Schematic...

Page 18: ...18 OM FX SERIES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 19: ...f the customer LABOR COVERAGE In the unlikely event a Unified Brands manufactured unit fails due to defects in materials or workmanship within the first ninety days Unified Brands agrees to pay the co...

Page 20: ...er cleaning temperature adjustments clogged drains unit leveling and re application of silicone 2 Unified Brands does not cover gaskets under warranty Gaskets are a maintenance type component that are...

Page 21: ...o minimize liability a full inspection is necessary upon arrival Appearance of damage will require removing the crate in the presence of the driver A notation must be placed on the freight bill and si...

Reviews: