![Uniden XDECT 8105 Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/uniden/xdect-8105/xdect-8105_owners-manual_3944243005.webp)
5
If..
Try..
x
you don’t hear a dial tone
x
the display says Registration
Failed
Making sure the handset is fully
charged, before trying again.
Test the Connection
Registration Methods
This handset is designed for use with XDECT 8115 and XDECT 8155
bases. For the most up-to-date list of compatible bases with this handset,
see our website.
Does the handset fit in the base cradle?
Yes
Place the handset in the base. The display should say
Registering
.
No
Does the base have an LCD display?
Yes
On the base, open the menu and select
Register Accy. The display should show
Registering
.
On the handset, press and hold
#DND
until the
display shows
Registering
(about 2 seconds).
No
On the base, press and hold
FIND HS
when the
phone is in standby (about 5 seconds).
On the handset, press and hold
#DND
until the
handset display shows
Registering
(about 2
seconds).
#
After about 30 seconds, the handset display should say Registration
Complete.
Pick up the handset and press
TALK/FLASH
. Make sure you get a dial
tone. (Press
END
to hang up.)
RESETTING THE HANDSET
If you are having trouble with a handset or if you want to replace one, you
need to clear the registration information from the base and the handset: