background image

15

Operation

Operating the UHF CB Radio in Duplex Mode

For this example we are adopting CH01 as the channel being used in 

your area for repeater use.

1. Press 

 2 times. The duplex setting flashes.

2. Turn the Channel Selector or press 

 / 

 to change the setting  

  between simplex and duplex (“ r ” for repeater channels 01 - 08 or “ n “ 

  for repeater channels 41 - 48).

3. Press 

 to store the setting.

4. Press and hold 

 to save & exit the menu mode. Only channels  

  01 - 08 and 41 - 48  are available for Duplex.

NOTE

Check with your local Retailer for information on available 

repeaters.

Scanning

The scan feature allows you to search for active channels automatically.

The UH5000 has two types of scanning; Open Scanning (OS) and 

Group Scanning (GS), to give you flexibility and allow you to use the 

radio more effectively.

1. Press 

 and Scanning starts. The 

 icon appears. The scan  

  direction can be changed at any time by rotating the channel selector  

  left or right.

UNIDEN UH5000

UHF CB Transceiver

Summary of Contents for UH5000

Page 1: ...UH5000 Mini Compact UHF CB Transceiver For more exciting new products please visit our website Australia www uniden com au ...

Page 2: ... Transmitting 13 Call Function 13 Using Repeater Channels 13 Operating the UHF CB Radio in Duplex Mode 15 Scanning 15 Open Scan OS Mode 16 Group Scan GS Mode Priority Watch 16 Add Remove Channels from SCAN Memory 17 CTCSS DCS 17 Busy Channel Lockout 18 Selecting the Call tone 18 Roger Beep 19 Beep On Off 19 Backlight Colours 19 Backlight Brightness 20 LCD Flip 20 CTCSS Codes Table 21 DCS Codes Tab...

Page 3: ...hannel programming One touch Instant channel recalling Selectable scanning type from group scan GS and open scan OS Scan channel memory On Off function separately divided into OS and GS Monitor On Off function Duplex capability Key Beep On Off function Rotary Channel select knob Busy Channel lock out function Roger beep function On Off 5 different CALL Tones 38 built in CTCSS Continuous Tone Coded...

Page 4: ...4 Controls Connectors 6 8 9 10 7 2 5 4 3 1 13 15 16 11 12 UNIDEN UH5000 UHF CB Transceiver 14 ...

Page 5: ...tton Scan Memory press hold 5 Liquid Crystal Display LCD 6 MIC Front Microphone Jack 7 Speaker 8 Power Input Connection 13 8VDC 9 EXT SP External Speaker Jack 10 UHF Antenna Connection 11 CALL Call Tone Button 12 INST Instant Channel Button 13 PTT Push To Talk Button 14 MICROPHONE 15 RJ45 type plug 16 Front MIC Jack Cover 5 Controls Connectors UNIDEN UH5000 UHF CB Transceiver ...

Page 6: ...hannel Busy Indicator Transmit Signal Power Level 2 Channel Number Menu Item Setting 3 CTCSS DCS Code number Menu Item 4 Scan mode 5 Channel in Memory 6 Instant Channel 6 Indicators 2 3 4 1 6 5 UNIDEN UH5000 UHF CB Transceiver ...

Page 7: ... www uniden com au for Australia Microphone Owner s Manual Microphone Hanger with screws washers Mounting Bracket with mounting screws DC Power Cord with fuse 7 Included with your UH5000 Transceiver UNIDEN UH5000 UHF CB Transceiver UH5000 Ultra Compact UHF Mobile Radio For more exciting new products please visit our website Australia www uniden com au ...

Page 8: ...is on the MIC cord to seal the MIC jack entry from dust Disconnecting the MIC from the MIC Jack Pull back the rubber cover and move it down along the cord Using the flat blade of a screwdriver or similar object carefully push the lock tab of the MIC plug towards the MIC cord and at the same time tug on the MIC cord to draw back the MIC plug 8 Connecting the Microphone UNIDEN UH5000 UHF CB Transcei...

Page 9: ...MIC Hanger into place with screws Conventional Mounting with Double Sided Tape not supplied High quality Double Sided tape can be found at good retail stores Secure the front and back pieces of the MIC Hanger using the supplied binding screws Locate a suitable mounting position Apply high quality Double Sided tape onto the flat area of the MIC Hanger back piece and then press firmly to the mountin...

Page 10: ...y occur to your radio which may not be covered by the manufacturer s warranty If the input voltage falls below 10VDC dc Lo flashes for 5 seconds The power turns off automatically if voltage falls below 8 5VDC Switch your UH5000 OFF and disconnect it from the power source before locating the cause of the power supply problem Setting the Squelch Level Press the Power Channel Selector momentarily SqL...

Page 11: ... weak signals can get through If unwanted weak and noisy signals are getting through increase the squelch level Squelch Gate to a medium level Now only medium and strong signals get through UNIDEN UH5000 UHF CB Transceiver oF off squelch open 1 max sensitivity min squelch 5 med sensitivity med squelch 9 min sensitivity max tight squelch NOTE You must select a channel which is not in use before set...

Page 12: ...nnel NOTE For your reference a list of the available channels corresponding frequencies and guidelines for their use and selection is printed on page 23 For Australia Channels 05 and 35 are reserved for Emergency Calls Programming the Instant Priority Channel Turn the Channel Selector to select the Priority Channel you prefer Press and hold INST on the microphone for 2 seconds to store the new set...

Page 13: ...n the microphone A three second ringing tone will be transmitted You may select from 5 types of tones see p 18 for Selecting the Call tone NOTE Current regulations require calling tones to be restricted to one transmission per minute If a second transmission is attempted within one minute then an error tone will sound Using Repeater Channels UHF CB Repeaters are used to retransmit or relay your si...

Page 14: ...ived by the Repeater Station and the re transmitted at the same time on another channel This operation is called Duplexing For example CH01 on Duplex Mode will Receive on CH01 but Transmit on CH31 CH02 on Duplex Mode will Receive on CH02 but Transmit on CH32 etc If you transmit on CH01 Duplex mode you are actually transmitting on CH31 the repeater station down converts your signal and retransmits ...

Page 15: ... Press and hold to save exit the menu mode Only channels 01 08 and 41 48 are available for Duplex NOTE Check with your local Retailer for information on available repeaters Scanning The scan feature allows you to search for active channels automatically The UH5000 has two types of scanning Open Scanning OS and Group Scanning GS to give you flexibility and allow you to use the radio more effectivel...

Page 16: ...ait 20 seconds for the signal to return otherwise scanning resumes To skip the active channel turn the Channel Selector Group Scan GS Mode Priority Watch Includes the accessory feature Priority Watch which allows you to monitor the Instant Priority Channel while scanning To use GS Mode Scanning 1 Press 3 times Scn shows and the oS GS setting flashes 2 Turn the Channel Selector or press to change t...

Page 17: ...ect the channel you want to store Press and hold to store The icon appears and a short tone is heard To remove the channel from SCAN memory press and hold once more The icon disappears CTCSS Continuous Tone Coded Squelch System DCS Digital Coded Squelch Turn the Rotary Channel Selector to the desired channel to use CTCSS or DCS 1 Press 1 time CTCSS DCS setting appears 2 Turn the Channel Selector o...

Page 18: ...Press 4 times The BCL setting flashes 2 Turn the Channel Selector or press to change the setting between ON or OFF 3 Press to store the setting 4 Press and hold to save exit menu mode Selecting the Call tone 1 Press 5 times The call tone setting flashes 2 Turn the Channel Selector or press to change the setting between 1 2 3 4 and 5 3 Press to store the setting 4 Press and hold to exit from the me...

Page 19: ...setting flashes 2 Turn the Channel Selector or press to change the setting between ON or OFF 3 Press to store the setting 4 Press and hold to save exit menu mode Backlight Colours 1 Press 8 times The Backlight setting flashes 2 Turn the Channel Selector or press to change the setting between Blue Red Purple magenta Green Cyan Yellow and Clear white 3 Press to store the setting 4 Press and hold to ...

Page 20: ...hannel Selector or press to change the setting between Off oF 1 Lo 2 mid and 3 Hi 3 Press to store the setting 4 Press and hold to save exit menu mode LCD Flip 1 Press 10 times The Flip setting flashes 2 Turn the Channel Selector or press to change the flip orientation 3 Press to store the setting 4 Press and hold to save exit menu mode ...

Page 21: ... 1 67 0 21 136 5 2 71 9 22 141 3 3 74 4 23 146 2 4 77 0 24 151 4 5 79 7 25 156 7 6 82 5 26 162 2 7 85 4 27 167 9 8 88 5 28 173 8 9 91 5 29 179 9 10 94 8 30 186 2 11 97 4 31 192 8 12 100 0 32 203 5 13 103 5 33 210 7 14 107 2 34 218 1 15 110 9 35 225 7 16 114 8 36 223 6 17 118 8 37 241 8 18 123 0 38 250 3 19 127 3 ...

Page 22: ... 261 81 506 12 065 47 263 82 516 13 071 48 265 83 523 14 072 49 266 84 526 15 073 50 271 85 532 16 074 51 274 86 546 17 114 52 306 87 565 18 115 53 311 88 606 19 116 54 315 89 612 20 122 55 325 90 624 21 125 56 331 91 627 22 131 57 332 92 631 23 132 58 343 93 632 24 134 59 346 94 654 25 143 60 351 95 662 26 145 61 356 96 664 27 152 62 364 97 703 28 155 63 365 98 712 29 156 64 371 99 723 30 162 65 ...

Page 23: ... to be added up to 80 Channels This simply means that the new narrowband radio you have purchased will have more channels than older radios Please refer to the guidelines above and the channel chart for further channel information A list of currently authorised channels can also be obtained from the ACMA website in Australia and the MED website in New Zealand Interference Poor Audio When a new nar...

Page 24: ... 3 476 475 477 225 CH33 23 476 975 RX only 4 476 500 477 250 CH34 24 477 000 5 476 525 477 275 CH35 25 477 025 6 476 550 477 300 CH36 26 477 050 7 476 575 477 325 CH37 27 477 075 8 476 600 477 350 CH38 28 477 100 9 476 625 29 477 125 10 476 650 30 477 150 11 476 675 31 477 175 12 476 700 32 477 200 13 476 725 33 477 225 14 476 750 34 477 250 15 476 775 35 477 275 16 476 800 36 477 300 17 476 825 3...

Page 25: ...477 2375 CH 73 63 future use 476 9875 RX only 44 476 5125 477 2625 CH 74 64 477 0125 45 476 5375 477 2875 CH 75 65 477 0375 46 476 5625 477 3125 CH 76 66 477 0625 47 476 5875 477 3375 CH 77 67 477 0875 48 476 6125 477 3625 CH 78 68 477 1125 49 476 6375 69 477 1375 50 476 6625 70 477 1625 51 476 6875 71 477 1875 52 476 7125 72 477 2125 53 476 7375 73 477 2375 54 476 7625 74 477 2625 55 476 7875 75 ...

Page 26: ...tail purchaser is only valid in the original country of purchase for a Product first purchased either in Australia or New Zealand If a warranty claim is made this warranty will not apply if the Product is found by Uniden to be A Damaged or not maintained in a reasonable manner or as recommended in the relevant Uniden Owner s Manual B Modified altered or used as part of any conversion kits subassem...

Page 27: ...ITION AND CONSUMER ACT 2010 Australia or the CONSUMER GUARANTEES ACT New Zealand as the case may be none of which can be excluded Procedure for obtaining warranty service Depending on the country in which the Product was first purchased if you believe that your Product does not conform with this warranty you should deliver the Product together with satisfactory evidence of your original purchase s...

Page 28: ...THANK YOU FOR BUYING A UNIDEN PRODUCT 2015 Uniden Australia Pty Limited Printed in Vietnam U01UT945HZZ 0 ...

Reviews: