background image

BUSY CHANNEL LOCK-OUT(BCL)

This feature prevents accidental transmission on a busy channel.

This is recommended on channels where CTCSS is being used. If the
channel is “active” and the signal is coming from a non or different
CTCSS code user the BCL feature will prevent you from transmitting.

To activate BCL                                

Press and hold 

[BCL]

for 1.5 secs until

“BCL”

appears on display.

To De-activate BCL

Press and hold 

[BCL]

for 1.5 secs. until

“BCL” disappears from the display.

MONITOR

This feature enables users to listen in for   
weak signals on the current channel at the
press of a button.

To use monitor,

• For brief listening, press 

[MON]

• For continuous listening. Press and

hold 

[MON]

for 2 sec. A two tone beep

will be heard and the receiver circuit
will stay open letting in both the noise
& weak signals. 

• Display shows 

MON

and 

BUSY

icons. 

• To return to normal receive mode

press 

[MON]

[PTT] [

]

or 

[

]

.

BCL

VOX

CTCSS

OS/GS

16

Summary of Contents for UH-052XR

Page 1: ...UH 052XR Operating Guide...

Page 2: ...y parts NICKEL CADMIUM BATTERY PACK WARNING This equipment contains a Nickel Cadmium Battery Pack The Nickel Cadmium Battery Pack contained in this equipment may explode if disposed of in a fire Do no...

Page 3: ...ing a Repeater Channel 9 To Operate UH 052XR in Duplex Mode 10 Scanning 10 Open Scan 10 Group Scan 11 Programming Scan Channels 12 Priority Channels 12 Drop Out Delay 12 Built in CTCSS 12 Built in VOX...

Page 4: ...g guide carefully before using the unit FEATURES Splash proof 40 Channels 5W 1W Switchable RF Output Power LCD Display Duplex Capability Group Scan Open Scan Monitor Built in Continuous Coded Squelch...

Page 5: ...e packaging that will provide adequate protection to your radio Enclose a note describing the problem a copy of your receipt and send it prepaid to AUSTRALIA NEW ZEALAND Uniden Australia Pty Ltd Unide...

Page 6: ...UH 052XR PACKAGE 3 Note If any of these items are missing from the box contact your Uniden Dealer Antenna AC Adaptor AAD 052S UH 052XR Wrist Strap Battery BP 052 7 2V 950mAh Operating Guide Product R...

Page 7: ...to turn the screw that connects the battery pack to the UH 052XR Be sure the battery pack fits tightly against the UH 052XR body CHARGING THE BATTERY PACK Your UHF CB radio is powered by a specially d...

Page 8: ...y empty CHG icon blinks or the display may totally disappear the radio will be unable to receive any signal and all the keys are disabled In this case it is best to switch OFF the radio to help facili...

Page 9: ...ockwise until a click is heard The display will disappear VOLUME Rotate the ON OFF VOL knob clockwise or counter clockwise to adjust speaker volume to desired listening level Note If no sound is heard...

Page 10: ...ything gets through noise weak signal and strong signals To set the Squelch Gate to the desired level turn SQ counter clockwise until you hear noise Then turn the SQ clockwise just until the noise sto...

Page 11: ...you transmit listen for activity on the selected channel 3 When the channel is clear press and hold the PTT to transmit TX appears on the LCD Hold the radio with microphone approximately two inches i...

Page 12: ...f a Repeater Station Operation with the aid of a Repeater With Duplex operation the signal coming from your radio is received by the Repeater station and then re transmitted at the same time on anothe...

Page 13: ...scanning starts Scan icon flashes during scanning 1 Open Scan OS Mode the absence of GS icon indicates that the unit is on OS mode Allows continuous scanning of channels stored in the Open Scan OS mem...

Page 14: ...e signal is present If the received signal ceases Priority scanning continues after 3 seconds If scanning stops on a channel which is not a Priority Channel UH 052XR will continue monitoring the Prior...

Page 15: ...Group Scanning is initiated is always the Priority Channel To change the priority channel setting while scanning eg PRI Channel is CH17 476 825 MHz a press to select a higher channel scanning pauses o...

Page 16: ...to change to CTCSS scan mode 3 During scanning and a signal is sensed on a CTCSS CH the UH 052XR stops for about 400msecs decode time to decode the CTCSS code If there is no code or the receive code d...

Page 17: ...ected level VOX icon stops blinking 4 Install VOX Headset not supplied to UH 052XR Installing VOX Headset 1 Remove SPEAKER MIC COVER 2 Attach VOX headset mic by pushing down jack through to the speake...

Page 18: ...ugh weather conditions The splashproof characteristic of this device complies to US Military Standard 810E Method 506 3 Rain II KEYPAD LOCK To prevent accidental entries you can lock the keypad Press...

Page 19: ...il BCL appears on display To De activate BCL Press and hold BCL for 1 5 secs until BCL disappears from the display MONITOR This feature enables users to listen in for weak signals on the current chann...

Page 20: ...52XR current battery voltage level at all times The battery level is displayed in 4 levels LEVEL 4 Battery 100 full LEVEL 3 Battery approx 50 capacity LEVEL 2 Low Battery LEVEL 1 flashing Empty Batter...

Page 21: ...477 050 Simplex 07 476 575 Simplex Duplex 27 477 075 Simplex 08 476 600 Simplex Duplex 28 477 100 Simplex 09 476 625 Repeater 29 477 125 Simplex 10 476 650 Repeater 30 477 150 Simplex 11 476 675 Back...

Page 22: ...eq Hz Code No Freq Hz Code No Freq Hz 00 oF OFF 13 103 5 26 162 2 01 67 0 14 107 2 27 167 9 02 71 9 15 110 9 28 173 8 03 74 4 16 114 8 29 179 9 04 77 0 17 118 8 30 186 2 05 79 7 18 123 0 31 192 8 06 8...

Page 23: ...d Loop Frequency Range 476 425 to 477 4 MHz Frequency Stability 6 ppm Power Output 5W high 1W low Spurious Emissions 65 dBc Current Drain 1500mA High 650mA low Receiver Receiver Type Dual Conversion S...

Page 24: ...Charger Std Power Supply AAD 052S Input 230 240V AC 50Hz Output 9V 210 mA Approval No V 00031 Specifications shown are typical and subject to change without notice 21...

Page 25: ...F CB Transceiver Unit only All accessories AC Adaptor Wrist Strap Battery and Antenna are covered for 90 days Statement of Remedy In the event that the product does not conform to this warranty at any...

Page 26: ...DC9V CHG CTCSS BCL OFF VOL SQ MEM LOCK 1 5W OS GS DUP SCAN MIC SPKR VOX CTCSS 2 3 1 4 5 7 8 UH 052XR 13 14 15 10 12 9 6 11 17 18 16 CONTROLS INDICATORS 23...

Page 27: ...e Key 14 Squelch Key 15 Speaker Mic Jack Cover 16 Scan and BCL Keys 17 Memory Key 18 Duplex and CTCSS Key A Transmit B 1W Power C Duplex Transmit D Scanning E Monitor F Priority G Busy Channel Lock Ou...

Page 28: ...2000 Uniden Australia Pty Limited Uniden New Zealand Limited Part Code UTZZ01872ZZ...

Reviews: