unicraft MV Series Operating Instructions Manual Download Page 5

Technical Data

MV-Series | Version 1.08

5

4

Technical Data

4.1 Table

4.2 Type plate

Fig. 2: Type plate

4.3 Dimensions

Fig. 3: Dimensions 

 

4.4 Accessories: Air transport hose

Fig. 4: Accessories: Air transport hose

- Air transport hose   Ø

 300 mm; Length: 10m

- Air transport hose   Ø

 500 mm; Length: 10m

- Air transport hose   Ø

 600 mm; Length: 10m

5

Transport, packaging, storage

5.1 Transport

Check the mobile fan after delivery for visible transport 
damage. If you discover any damage, immediately 
report it to the transport company or the dealer. 

5.2 Packaging

All packaging materials and packaging aids used are 
recyclable and must always be recycled.

Packing components made of cardboard are shredded 
for waste paper collection.

The foils are made of polyethylene (PE), the upholstery 
parts made of polystyrene (PS). You can hand over 
these substances to a recycling center or to the dispo-
sal company responsible for you.

5.3 Storage

Clean the mobile fan, oil the bearings and store it in a 
frost-free and dry environment. Do not put anything on 
the fan. 

MV 30

MV 50

MV 60

Impeller Ø

300 mm

500 mm

600 mm

Voltage

230V / 

50 Hz

230V / 

50 Hz

230V / 

50 Hz

Speed [rpm]

2800

1400

1400

Performance 

500 W

1100 W

2000 W

Air flow rate          
[m

3

/min]

65

130

240

Degree of                 
protection 

IP 54

IP 55

IP 55

Weight 

15 kg

39 kg

64 kg

Sound pressure   
level

69 

dB(A)

73 

dB(A)

79 

dB(A)

MV 30

MV 50

MV 60

L

380 mm

480 mm

580 mm

D1

375 mm

580 mm

680 mm

D

303 mm

504 mm

605 mm

H

430 mm

755 mm

870 mm

NOTE!

Protect the device from moisture.

Summary of Contents for MV Series

Page 1: ...MV S ERIES MV 30 Operating Instructions Mobile Fan MV 30 MV 50 MV 60 MV 50...

Page 2: ...re prohibited if not explic itly permitted Contraventions are liable to compensa tion Subject to technical modifications and error Content 1 Introduction 3 1 1 Copyright 3 1 2 Customer service 3 1 3 L...

Page 3: ...aluable for the improvement of our products 1 3 Limitation of liability All information and instructions in this manual have been compiled taking into account the applicable standards and regulations...

Page 4: ...s well as for cooling and drying objects It is not explosion proof and is not intended for outdoor use The fan may be operated only by instructed persons Proper use also includes compliance with all i...

Page 5: ...components made of cardboard are shredded for waste paper collection The foils are made of polyethylene PE the upholstery parts made of polystyrene PS You can hand over these substances to a recyclin...

Page 6: ...al electric shock Contact with live components may result in fatal injury CAUTION Danger of crushing Improper work on the mobile fan may result in injury to fingers and hands Never insert your fingers...

Page 7: ...llowing key data for inquiries or ordering spare parts device type item number Position number Construction year amount desired shipping method post freight sea air express delivery address Spare part...

Page 8: ...In case of service the following drawings shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised dealer Fig 6 Spar...

Page 9: ...Electrical circuit diagrams Mobile Fan Version 1 08 9 10 Electrical circuit diagrams Fig 8 Electrical circuit diagrams MV 30 top MV50 MV 60 bottom MV 30 MV 50 MV 60...

Page 10: ...ies with all relevant provisions of the above mentioned directive as well as the other applied directives below including their applicable modifications at the time of the declaration EU directive 201...

Page 11: ...Notes Mobile Fan Version 1 08 11 12 Notes...

Page 12: ...www unicraft de...

Reviews: