Installation
Size
Fire proof door
Front Ass'y
(Front body)
Back Ass'y
(Main body)
Password
Smart key
Door thickness 40 ~ 50mm
68(W) x 173(H) x 24(D) mm
94(W) x 160(H) x 40(D) mm
4 ~ 12 digit (up to 3 password can be registered)
Digital key
Up to 100 keys can be registered (315D)
Up to 100 keys can be registered (315S)
Classfication
Specification
Specification of product
Open type
* Lifetime of the batteries is based on the result of the tests by the company and is not an
absolute measurement. It will vary depending on the temperature and humidity of the
installed location as well as the frequency of usage and the quality of batteries.
* Function, design and composition of the product may change without any prior notice
for the purpose of improving the quality.
Double Locking mode
When all family members are in home, this
safe mode allows no one can open the door
using password or digital key or smart key
from outside.
Press [Open/Lock] button of the Back Ass'y
for more than 3 seconds and double locking
is activated.
When setup is done, you will hear beep sound.
Press [Open/Lock] button of the back ass'y or
open the door with [Manual lock knob] and
double locking mode is deactivated.
Double Locking mode
※
When double locking is set, the door will not be opened by password or
digital key or smartkey from outside.
▶
Unsetting
▶
Setting
Battery replacement notification
When batteries are completely discharged making it impossible to open the door,
this function allows the user can open the door using 9V battery from outside.
Contact DC 9V battery to external power supply
terminal and open the door using registered
password or digital key or smart key.
When it's time to replace batteries, you will hear melody sound to let you
know when open or lock the door.
When you hear this melody, open battery cover and replace all batteries with
1.5V Alkaline batteries.
Attention
●
Must use general batteries, not rechargable ones.
●
Please be careful of batteries' polarity because it can cause leakage or
rupture if placed wrongly.
●
Must replace all old batteries with new ones, not partially. Do not use new ones
with discharged ones together.
●
It is designed to operate with the rated voltage 6V. If low voltage(4.2V ±0.3V) is
detected, melody will be generated.
●
If the door lock stops working or batteries are discharged in a short period of
time after replacement, the batteries could be defective. It is required to
contact the shop where the user purchased batteries and get new ones as
replacement.
Emergency Power Supply
●
You can use 9V battery regardless of battery polarity.
●
Please remain contact of 9V battery onto the power supply terminal so that
emergency power is supplied (not rechargable).
●
Replace all discharged batteries with new ones right after emergency
power is supplied.
Caution
High-temperature warning system
▶
Releasing high-temperature warning sound
When high temperature over 70
℃
±10
℃
is detected, it generates warning
sound over 80dB.
If incorrect password or digital key or smart key is entered 3 times consecutively,
warning sound is generated and all functions are disabled for 30 seconds.
If the deadbolt is not working properly 3 times
when open or lock the door, it generates
melody as a warning signal.
Warning sound is disabled when registered password or
digital key or smart key is entered or batteries are removed.
Trespass / Breakage alarm
30 seconds LOCK function
Notification function of the deadbolt jam
It is released when the power is reset by
removing batteries.
※
It is not released when the temperature
of the product is high.
If there's any attempt to open the door by abnormal way
such as widening the door gap, it generates 80dB warning
sound with blink.
▶
Releasing warning sound
▶
Operation
If you keep experience warning sound or malfunction of the lock,
you need to adjust the position of the lock again.
Attention
Attention
When warning sound is generated, the door opens automatically
regardless of Double locking or Forced lock setting.
Warning sound disabled
- [7] button : If pressed repeatedly, volume will be reduced gradually.
- [8] button : Silence (except warning sound)
- [9] button : If pressed repeatedly, volume will be increased gradually.
(Default setting is stage 4 of basic setting. )
Volume Control
The user can set the volume from silence to stage 6.
▶
Setting
[Register button] - [ # ] -
- [Register button]
[ 7 ] : Volume down
[ 8 ] : Silence
[ 9 ] : Volume up
Push up [Keypad cover] and press
[#]
button for 1 time.
Enter registered password and press
[
]
button.
Etiquette mode
Regardless of the current sound setting, this function makes
the door lock silent for 1 time when the user wants to use
it quietly.
※
This is one-time function so sound will be generated
from next time.
This function is for apartments and other buildings with multiple households.
It may be deleted upon moving in.
Master password registration & deletion
(Password / Digital key / Smart key)
[Register button]- [
8
] - [
3
] - [Register button] - [
4 ~ 12 digit numer
] - [Register button]
Registration
Registration
Deletion
Deletion
[Register button] - [
#
] - [
#
] - [
#
] - [
7
] - [
3
] - [Register button] - [ ]
- [Register button]
▶
Master password
▶
Key
registered password or
master password
[Register button]- [
8
] - [
6
] - [Register button] - [
key contact
] - [Register button]
[Register button] - [
#
] - [
#
] - [
#
] - [
7
] - [
6
] - [Register button] - [ ]
- [Register button]
registered password or
master password
Press [
0
] button after push up
[Keypad cover] from outside and
press [
] button for 5 seconds.
If the user opens the door using registered password, digital key or smart key from
outside, the setting is released automatically.
Forced lock setting/unsetting from outside
This function helps strengthen the level of security by generating poweful
warning sound if someone tries to unlock the door from inside when the user
leaves home for long period of time.
▶
Unsetting
▶
Setting
[Register button]
[Register button]
[Register button]
[Register button]
Intrusion alert (Human hands detection system)
This function prevents intrusion by drilling a hole on the door or pressing the
door open button with stick or metal wire and it makes the door open only by
human hands.
▶
Setting
▶
Unsetting
If the password is '1234', enter fake password(random numbers) before real
password, enter '1234' and the door will be opened.
※
Fake numbers(random numbers) + real password should not exceed 20 digit.
After entering fake numbers
(random numbers)
press '1234'
Entering trick numbers to prevent exposure password
If there's watchful person when the user enter password, this function allows
the user can protect password by entering fake password before real password.
▶
How to use
※
If the door is opened by [Open/Lock] button or manual lock knob from
inside, double locking mode is released automatically.
Double Locking unsetting from outside
This function allows the user can unset double locking mode from outside
in case of setting double locking mode by mistake.
▶
Unsetting
1. While the door is locked, Push the [keypad cover] up and enter the
registered password.
2. Press the [
#
] button and press the password and press the [
] button again.
Warranty
◎
The warranty period for all of the company’s products is 1 year from the date of
purchase indicated on the warranty certificate.
◎
Even during the warranty coverage, users need to pay (the cost for trip, technical
support and parts) for some services if they are in the category of chargeable services.
◎
User generally submit the warranty certificate or other methods that contains the
installation information when needed to request a service.
◎
If the warranty certificate is not available, users need to submit a receipt, a credit card
receipt or a cash receipt instead (Except for a simple receipt)
◎
◎
If it is impossible to show the purchase date, the warranty period will be applied by
taking into consideration the product’s manufactured date + expiration period
(6 months)
* Details of mistakes and mishandling by the user
For products pruchased outside of Korea, please consult your local distiriboutor or
reseller as warranty policies vary from country to country.
Types of consumer damage
Content of compensation
Within the warranty period After the warranty period
The product
is used in
normal
conditions
Failure occurs within 1 month from date of purchase
Failure occurs within 1 year from date of purchase
Same failure occurs 4 times or more
The repair parts are not available at the main office
Product replacement
Free-of-charge repair
Free-of-charge repair
Product replacement
Paid repair
Replacement after depreciation
based on a fixed rate.
Mistakes and
mishandling
by the user
Not the case of failure
Mistakes and mishandling by the user
Defective installation, and other reasons
Paid repair
Not the case of failure
Mistakes and mishandling by the user
Other reasons
When needed to break the
product due to the loss of
secret code.
When the door is sagging, or
installation is defective, requiring
the product to be reinstalled.
Request for checking the product
for possible problems while
there is no specific symptom of
a failure.
Problems in operation occur after
the user installs the product
directly.
A visit for repair is needed as
there are mistakes and mishan
dling by the user such as mistakes
in replacing batteries and unskill
ful use of the product.
Defective operation due to poorly
inserted batteries and use of
defective batteries.
Failure and breaking due to the
use of the product for other
purposes.
Failure and breaking caused by
the user on purpose or from an
external impact.
Failure and damage due to natu-
ral disasters such as fires, floods,
and damage from sea water.
Penetration by water, condensa-
tion and injection of chemicals,
requiring the internal circuits to
be replaced, and causing failures.
UNICOR HIGHTECH CO., LTD
62 EunCheong Street, Namdong-Gu,
Incheon, Korea (zip. 21643)
Warning sound disabled
if batteries are removed.