background image

Unicont SPb Ltd 

 

Installation Manual MV-1901F 

 Page 

5.

  Installing and connecting the display 

The display is installed and connected in the following sequence: 

1.

 

Insert the frame with LCD display into rack radar in place of CRT dismantled 

(Figure 12). 

 

 

 

Figure 12. Mounting display into radar rack 

IMPORTANT!

 If necessary, shorten (cut away) fastening bolts of CRT fixing it to 

radar rack. 

 

IMPORTANT!

 Do not tighten the frame bolts up to the end of connecting cables to the 

display. 

2.

 

Fix the bracket with switching card on the inner part of the left-hand side of radar 

rack (Figure 13). 

 

Mounting points 

fixing switching 

card to radar rack

 

Figure 13. The location of switching card (on the left), general view of switching card 

in radar rack (on the right) 

 

Connecting LCD display 

LCD display is connected in the following sequence (also see Table 1, Figure 16): 

3.

 

Insert control cable (14-conductor ribbon cable) coming out from the hole (on the 

back side) of LCD-display housing into J1 connector of the switching card (Fifure 14, 
Figure 15). 

Summary of Contents for MV-1901F

Page 1: ...Unicont SPb Ltd LCD Display MV 1901F Repair kit for replacing CRT in Furun radar FR 2115 2125 Installation Manual 0F 1 15082013 St Petersburg 2013...

Page 2: ...NFORMATION 3 2 DELIVERY SET 3 3 SPECIFICATIONS 3 4 INSTALLING AND CONNECTING THE DEVICE 4 5 INSTALLING AND CONNECTING THE DISPLAY 9 6 CONTROLS 12 7 TRANSPORTATION AND STORAGE 13 8 RECYCLING 14 9 WARRA...

Page 3: ...1 pc 3 Switching card with buttons and bracket 1 pc 4 Power cable 1 pc 5 Installation Manual 1 pc 3 Specifications Parameter MV 1901 Display diagonal 19 Supply voltage 88 264 V AC Power consumption 80...

Page 4: ...isconnect it from the following cables also see Figure 1 power supply cable connector J576 from radar power supply unit potentiometer cable of brightness control dimmer connector J579 RGB VGA signal c...

Page 5: ...p unit and other devices 4 Remove cables and cards from CRT 5 Remove mounting bolts located at 4 corners of the frame from the CRT display protective frame see Figure 3 Mounting bolt of protective fra...

Page 6: ...Unicont SPb Ltd Installation Manual MV 1901F Page 6 Figure 4 CRT frame view removed from radar rack 7 Remove CRT from radar rack Figure 5 Figure 5 Dismantling CRT from radar rack...

Page 7: ...pearance of MV 1901F display Preparation of LCD display for installation into CRT frame 1 Remove the device and all components from the package 2 Using special bolts supplied complete with the display...

Page 8: ...rs should be faced to the bottom side of the frame Figure 10 The order of arranging brackets in the frame 5 Fix LCD display in CRT frame so that mounting brackets of LCD display are located above the...

Page 9: ...e frame bolts up to the end of connecting cables to the display 2 Fix the bracket with switching card on the inner part of the left hand side of radar rack Figure 13 Mounting points fixing switching c...

Page 10: ...wer supply cable removed from J576 connector to J3 connector IN 140 V of the switching card Figure 15 connect dimmer control cable removed from J579 connector to J2 connector dimmer of the switching c...

Page 11: ...J2 Cable removed from J579 connector Control signals J1 14 conductor ribbon cable Video signal Cable removed from RGB connector VGA connector OUT 140 V IN 140 V DIMMER PLUS MINUS MENU SET POWE R J 1 J...

Page 12: ...s selecting menu items change values of parameters In the menu these buttons allow you to scroll thorough the items setting When changing settings allow you to increase decrease the value 5 Backlight...

Page 13: ...rt automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in accorda...

Page 14: ...You can also send the overage equipment to the manufacturer for its further recycling Proper recycling of the product components will prevent potential negative consequences for human health and the e...

Page 15: ...ondition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who is not an aut...

Page 16: ...s manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control representative St...

Reviews: