Unicont SPb Ltd
Technical Documentation DAC-109
Page
14
6.2
Configuration Menu of the Converter
When pressing the key [F3] in the standby mode of the converter (see par. 6.1) the configuration menu
appears at the display of DAC-109:
Exit from this menu to the standby mode of the converter is performed by the key [F3] (the set
configurations are stored).
The name of configured parameter is displayed in the upper line of the display. The current value of
this parameter is displayed in the lower line.
Selecting a parameter is performed by pressing the keys [
▲
] and [
▼
], changing the value of selected
parameter is performed by pressing the keys [
◄
] and [
►
]. Confirmation of selected parameter value
and its storing in the permanent memory of the converter is performed by pressing the key [Enter].
The settings of the converter which may be changed and their purpose are listed below.
Frequency Choice
Selection of the output sinusoidal analogue signal frequency.
The frequencies which are available: 50 Hz, 500 Hz
Repeater Type
Selection of the type of the connected repeaters.
The repeater types which are available: Step, Synchro
Reference Voltage
Selection of the output level on the reference channel. This is ratio of voltage which is setup by P12
and P21 (see section 5).
Available values: 100%, 95%. 90%, 85%, 80%, 75%, 70%, 65%, 60%, 55%, 50%, 45%, 40%, 35%,
30%, 25%, 20%, 15%, 10%, 5%.
Phase Voltage
Selection of the output level on the phase channels. This is ratio of voltage which is setup by P12 and
P21 (see section 5).
Available values: 100%, 95%. 90%, 85%, 80%, 75%, 70%, 65%, 60%, 55%, 50%, 45%, 40%, 35%,
30%, 25%, 20%, 15%, 10%, 5%.