background image

Smart-Switch/801

19

Technical Specifications

Standards Compliance

IEEE 802.3 10Base-T Ethernet,

IEEE 802.3u 100Base-TX/FX Fast Ethernet

IEEE 802.3x Flow Control

Protocol

CSMA/CD

Max Forwarding and

Max Filtering Rate

14,880 pps per Ethernet port,

148,800 pps per Fast Ethernet port

 Packet size

64 ~ 1522 bytes

 LED Diagnostic Indicators

Per Port: (10/100 UTP ) :

10/100M, LK/ACT, FD/COL ( 3 LEDs )

Fiber Port: LK/ACT, FD/COL ( 2 LEDs ) 

Per Unit: Power

Copper Network Cables

10Base-T: 2-pair UTP/STP Cat5e/6 cable

EIA/TIA-568 100-ohm ( 100m )

100Base-TX: 2-pair UTP/STP Cat5e/6 cable

EIA/TIA-568 100-ohm ( 100m )

Fiber Link Max. Distance

SC/ST, Multi-mode: 2km

SC, Single-mode: 30km

Dimensions

250mm x 132mm x 37mm (L x W x H)

Weight

1050 

±

20 g

Storage Temp.

-40ºC to 70ºC ( -40ºF to 158ºF)

Operational Temp.

0ºC to 45ºC ( 32ºF to 113ºF )

Operational Humidity

10% to 90% (Non-condensing)

External Power

100-240V AC, 50-60Hz

Power Consumption

10 Watts ( Max )

EMI

FCC Class B, CE Mark

Safety

UL, cUL

Get user manuals: 

See SafeManuals.com

 

 

Summary of Contents for Smart-Switch/801 FEP-30109T-C

Page 1: ...8 Port 10 100Base TX Switch with 100Base FX Smart Switch 801 USER S MANUAL SC MM FEP 30109T C ST MM FEP 30109T T SC SM FEP 30109T C SM Model shown FEP 30109T C Get user manuals See SafeManuals com ...

Page 2: ...ingle Mode Back Pressure Base flow control on Half duplex mode Pause Frame Base flow control on Full duplex mode Store and forward architecture for abnormal packet filtering 2K entry MAC address table 96Kbytes memory buffer sharing Non blocking and Full wire speed forwarding rate One console port for VLAN configuration and Port Setting LED indicators for Power 10 100 LK ACT and FD COL 10 Desktop s...

Page 3: ...elow Smart Switch 801 Fast Ethernet Switch Power Cord Four Rubber Feet RS 232 console management cable User Guide Smart Switch 801 Power Cord Rubber Feet RS 232 cable User Guide Figure 1 2 Package Contents If any item is missing or damaged please contact your local dealer for service Get user manuals See SafeManuals com ...

Page 4: ...00Base FX fiber port and the LED indicators Smart Switch 801 with SC Connector Figure 2 2 The Front Panel of the Smart Switch 801 with SC connector Smart Switch 801 with ST Connector Figure 2 3 The Front Panel of the Smart Switch 801 with ST connector RJ 45 Ports Auto MDI MDIX Eight 10 100 auto sensing for 10Base T or 100Base TX connections 100Base FX Fiber Port The operating range for the Multi M...

Page 5: ...tatus Color Description Power On Green Power On On Green The port is operating at 100Mbps 10 100 Off The port is operating at 10Mbps or no device attached On Green The port is successfully connecting with the device Blinks Green The port is receiving or transmitting data LK ACT Off No device attached On Orange The port is operating in Full duplex mode Blinks Orange Collision of Packets occurring w...

Page 6: ...e port is receiving or transmitting data LK ACT Off No device attached On Orange The port is operating in Full duplex mode Blinks Orange Collision of Packets occurring within the port FDX COL Off The port is operating in Half duplex mode or no device attached Table 2 1 Descriptions of LED Indicators Get user manuals See SafeManuals com ...

Page 7: ...ation is done through the console port connector This requires a direct connection between the switch and a device such as a PC or terminal using the supplied RS 232 cable Desktop Installation Set the switch on a sufficiently large flat space with a power outlet nearby The surface should be clean smooth level and sturdy Make sure there is enough clearance around the Switch to allow air circulation...

Page 8: ... from shock and vibration Figure 2 6 Attaching Rubber Feet to each corner on the bottom of the Switch Power On Connect the power cord to the power socket on the rear panel of the Switch The other end of the power cord connects to the power outlet The internal power supply in the Switch works with AC in the 100 240VAC frequency 50 60Hz voltage range Check the power indicator on the front panel to e...

Page 9: ...h is used Desktop Application The Smart Switch 801 can be used as a desktop switch an ideal solution for a small workgroup Used as a standalone switch personal computers servers and printer servers are directly connected to form a small workgroup Figure 3 1 Desktop Application Get user manuals See SafeManuals com ...

Page 10: ...er by connecting these devices directly to the Smart Switch 801 All devices in this network can communicate with one another as well as with central servers The Switch automatically learns node addresses which are subsequently used to filter and forward all traffic based on the destination address You can interconnect each of your small switched workgroups to form a larger switched network through...

Page 11: ... Use fiber port Smart Switch 801 to extend the distance between workgroups In the above illustration two Smart Switch 801 switches are used to connect two small workgroups By using fiber ports to connect switches the distance between the two switches can extend up to 2Km Multi Mode or 30Km Single Mode fiber Get user manuals See SafeManuals com ...

Page 12: ...itch Connecting a Terminal or PC to the Console Port Figure 4 1 Connecting the Smart Switch 801 to a terminal via RS 232 cable Use the supplied RS 232 cable to connect a terminal or PC to the console port The terminal or PC to be connected must support a terminal emulation program Once connected turn on the PC and run a standard terminal emulation program such as Hyper Terminal or Windows Terminal...

Page 13: ...Stop Bit 1 Flow Control None Figure 4 2 The settings of communication parameters After you have finished parameter settings press OK The main console management menu should appear You need to reboot the Switch to show Main Menu Get user manuals See SafeManuals com ...

Page 14: ...appears see fig 4 4 The default Per Port Settings are all Auto Negotiation and the default fiber port setting is 100M Full duplex mode To modify a port s status first choose the port number In the following example we choose Port 1 by typing 1 Five different port duplex modes are available Auto Negotiation Force to 100M and FDX mode Force to 10M and FDX mode Force to 100M and HDX mode Force to 10M...

Page 15: ...tual LAN is a group of switch ports designated by the switch as belonging to the same broadcast domain This feature allows workgroups to be defined on the basis of their logical location instead of their physical location VLANs also help isolate broadcast traffic and increase security Get user manuals See SafeManuals com ...

Page 16: ... the Main Menu choose the second item Setting VLAN by typing 2 Follow the VLAN Setup Menu The switch can support up to nine VLAN groups Figure 4 6 VLAN Setup Menu First type in the port number and the prompt displays Enter VLAN ID number 1 9 Then choose the required VLAN group number by typing the VLAN ID number Type in 1 to add to this VLAN ID or 2 to remove from this VLAN The display will now sh...

Page 17: ...member Restore Factory Setup If you make a mistake while setting up any of the menus you can easily restore the switch setting to the factory default by selecting the main menu choosing the 3rd item Restore Default Setup by typing 3 The switch will reset to the original factory settings Reset Device If the switch performs improperly or if you want to reboot the switch go back to Main Menu and sele...

Page 18: ... and can seriously impair network performance A Category 5e cable tester is a recommended tool for every 100Base T network installation Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include excessive cable length and too many repeaters hubs between end nodes In addition you should make sure that your network topology contains...

Page 19: ...ologies RJ 45 ports Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections Category 3 5e or 6 cable for 10Mbps or Category 5e and 6 cable for 100Mbps connections Ensure that the length of any twisted pair connection does not exceed 100 meters 328 feet 100Base FX fiber port The Multi Mode Fiber connector type must use 50 125 or 62 5 125µm MM fiber cable You can con...

Page 20: ...r Port LK ACT FD COL 2 LEDs Per Unit Power Copper Network Cables 10Base T 2 pair UTP STP Cat5e 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat5e 6 cable EIA TIA 568 100 ohm 100m Fiber Link Max Distance SC ST Multi mode 2km SC Single mode 30km Dimensions 250mm x 132mm x 37mm L x W x H Weight 1050 20 g Storage Temp 40ºC to 70ºC 40ºF to 158ºF Operational Temp 0ºC to 45ºC 32ºF to 113ºF ...

Page 21: ...Smart Switch 801 20 Get user manuals See SafeManuals com ...

Page 22: ... 346 6668 Fax 626 964 7880 www unicomlink com e mail info unicomlink com UNICOM 2005 UNICOM and A Network Systems Solution are trademarks of UNICOM Electric Inc All rights reserved Specifications subject to change without notice Rev 09 05 Get user manuals See SafeManuals com ...

Reviews: